DCP-3060
Loudspeaker Management System
User Manual
XILICA Audio Design

Advertisement

Table of Contents
loading

Summary of Contents for Xilica Audio Design DCP-3060

  • Page 1 DCP-3060 Loudspeaker Management System User Manual XILICA Audio Design...
  • Page 2: Important Safety Instructions

    This product should not be placed in a built-in installation such as a bookcase or rack unless proper ventilation is provided or the manufacture's instructions have been adhered to. DCP-3060 User's manual - Page 2...
  • Page 3 15. WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPARATUS TO RAIN OR MOISTURE. 16. APPARATUS SHALL NOT BE EXPOSED TO DRIPPING OR SPLASHING AND NO OBJECTS FILLED WITH LIQUIDS, SUCH AS VASES, SHALL BE PLACED ON THE APPARATUS. DCP-3060 User's manual - Page 3...
  • Page 4: Table Of Contents

    6.0 Operating the Device ........... 11 6.1 Input menus............. 11 6.2 Output Menus............13 6.3 System Menus............17 7.0 Quick Reference............20 8.0 PC Control Software ............ 21 9.0 Specifications............... 22 10.0 Warranty................ 24 DCP-3060 User's manual - Page 4...
  • Page 5: Introduction

    1.0 Introduction The DCP-3060 is a complete 3 input - 6 output digital loudspeaker management system designed for the touring or fixed sound installation markets. The absolute latest in available technology is utilized with 32-bit (40-bit extended) floating point processors and high performance 24-bit Analog Converters.
  • Page 6: Features

    2-Line x 16 Character Backlit LCD Display > Full 5-segment LED’s on every Input and Output > Storage of up to 30 Program Setups > Security Lock > RS-232 Interface for PC Control and Configuration > Future options available DCP-3060 User's manual - Page 6...
  • Page 7: Front Panel Functions

    100X. 6. Menu Control keys - There are 6 menu keys: <<Menu (Menu Down), Menu>> (Menu Up), <<Cursor (Cursor Down), Cursor>> (Cursor Up), Enter/Sys/Speed and Exit. The functions of each key is explained below: DCP-3060 User's manual - Page 7...
  • Page 8 Enter/Sys/Speed: Enter is used only in the System Menu to proceed with selected actions Sys enters the System Menu from the main menu Speed modifies delay and frequency (1 Hz resolution mode) data values by 100X. Exit: Exit to the Main Menu DCP-3060 User's manual - Page 8...
  • Page 9: Rear Panel Functions

    6. XLR input and outputs - Separate 3-pin XLR connectors are provided for each audio input and output. The device's output stage employs the balanced impedance topology. All I/O connectors have pin 1 as ground (shield), pin 2 as + and pin 3 as -. DCP-3060 User's manual - Page 9...
  • Page 10: Powering Up The Device

    DCP-3060 - INITIALIZING - • The initialization process takes about 8 seconds and during that period the unit boots and displays the DCP-3060 firmware version. • After the initialization process is finished the DCP-3060 displays its main screen: XILICA DCP-3060 P01 XXXXXXXXXXXX •...
  • Page 11: Operating The Device

    Menu key or the Sys key after releasing the held key. Input menus Each of DCP-3060 input channels has a separate Menu key. There are 3 menus for each input channel. Signal - Signal parameters •...
  • Page 12 • Type - Type of EQ. The types can be parametric (PEQ), Lo-shelf (Lo-shf) and Hi-shelf (Hi-shf). I1:XXXXXX EQ Type:PEQ Ch-Name - Channel Name I1:XXXXXX ChName NAME:XXXXXX • Name - Channel name. It is 6 characters in length. DCP-3060 User's manual - Page 12...
  • Page 13: Output Menus

    Output Menus Each output channel of the DCP-3060 has a separate menu key. There are 6 menus for each output channel. Signal - Signal parameters • Refer to the Input Menus for details EQ - EQ paramters • Refer to the Input Menus for details...
  • Page 14 O1:XXXXXX XOver FTRH:Off • FRQH - Filter cut-off Frequency of high frequency crossover point (low pass). O1:XXXXXX XOver FRQH:1000Hz • SLPH - Filter Slope of high frequency crossover point (low pass). O1:XXXXXX XOver SLPH:24dB DCP-3060 User's manual - Page 14...
  • Page 15 • ATTACK - Attack time. Ranges from 0.3 to 1ms in 0.1ms steps, then ranges from 1 to 100ms in 1ms steps. O1:XXXXXX Limit ATTACK:10ms • RELEASE - Release time. Can be set at 2X, 4X, 8X, 16X or 32X the attack time. O1:XXXXXX Limit RELEASE:8X DCP-3060 User's manual - Page 15...
  • Page 16 O1:XXXXXX Source In1:On O1:XXXXXX Source In2:Off O1:XXXXXX Source In3:Off Ch-Name - Channel Name • Refer to the Input Menus for details DCP-3060 User's manual - Page 16...
  • Page 17: System Menus

    Recall - Program Recall The DCP-3060 has a built in non-volatile memory that can store up to 30 different program setups. A program can be recalled using this menu. • PROG - Program Number to be recalled. Only first 8 characters of the program name is displayed.
  • Page 18 When one of the Source or the Target is an input while the other is an output, only the Level, Polarity, Delay and EQ are copied. • SOURCE - Channel to be copied from. O1:XXXXXX Copy SOURCE:In1 • TARGET - Channel to be copied to. O1:XXXXXX Copy TARGET:In2 DCP-3060 User's manual - Page 18...
  • Page 19 O1:XXXXXX Generl DEVICE#:1 Security - Security Lock The DCP-3060 enables the user to secure the unit and prevent undesired changes in the setup. In order to lock/unlock the unit the user must enter the correct password. • PASSWORD – The password of the DCP-3060 is 4 characters in length.
  • Page 20: Quick Reference

    Out Attack Time Limit ATTACK 0.1/1 Out Release Time Limit RELEASE 2 / 4 / 8 / 16 / 32X Attack time Source Source 1, 2, 3 Off / On Channel Name Ch-Name NAME 6 characters DCP-3060 User's manual - Page 20...
  • Page 21: Pc Control Software

    8.0 PC Control Software The DCP-3060 is shipped with a special PC Graphic User Interface (GUI) application - XLink. XLink gives the user an option to control the DCP-3060 unit from a remote PC via the RS232 serial communication link. The GUI application makes it much easier to control and monitor the device, allowing the user to get the whole picture on one screen.
  • Page 22: Specifications

    6 Menu Controls Dial Encoder: Embedded Thumb Wheel Connectors Audio: 3-pin XLR RS-232: Female DB-9 Power: Standard IEC Socket General Power: 115 / 230 VAC (50 / 60Hz) Dimensions: 19”x1.75”x8” (483x44x203 mm) Weight: 10lbs / 4.6kg DCP-3060 User's manual - Page 22...
  • Page 23 Program Names: 12 character length Delay Units: ms, ft, m Frequency Modes: 36 steps/oct, 1Hz resolution Security Lock: Lock/Unlock Copy channels: All parameters Channel Names: 6 character length Note: Specifications subject to change without notice DCP-3060 User's manual - Page 23...
  • Page 24: Warranty

    10.0 Warranty The DCP-3060 is warranted covering materials and workmanship for a period of one (1) year, as determined by the date of retail purchase (according to the sales receipt from an authorized dealer) or the date of manufacture if the sales receipt is not available (according to the serial number).
  • Page 25 User Manual v4.01 (Apr 2005) XILICA Audio Design 88 Oxford Street, Richmond Hill, Ontario, Canada. L4C 4L5 Phone: (905) 770-0055 Fax: (905) 770-2984 www.xilica.com...