If a problem occurs

All electrical appliances can be affected by faults.
As this does not always mean that the appliance is
defective, please use the table to check whether
you can remedy the fault yourself.
Problem
Compressor and interior
light off.
Compressor is not running,
interior light is on.
The appliance is cooling too
much.
The appliance does not cool
enough.
The appliance is noisy.
Trouble-shooting table
Possible cause
No current in the wall outlet.
Mains plug is not tight.
The required temperature has been reached.
New installation.
Ambient temperature too low (less than +16 °C)
The temperature of the inner compartment has
been set to too low a cooling level.
The wrong temperature has been selected.
The door is not closed tight or the door seal does
not make proper contact throughout.
Food is not cooled.
Too many products have been put in at once.
A layer of ice has formed.
The ambient temperature is too low or too high
Several operating noises can be produced de-
pending on the current operation; they do not
mean that a fault has occurred.
Irritating noises.
Danger!
Never try to repair the appliance when it has
or seems to have broken down. This might
endanger yourself and future users. Repairs
must only be carried out by authorised pro-
fessional staff.
Solutions, tips
Connect another appliance to check.
Make sure that the mains plug has been inserted
properly.
Further cooling is not required. When the inside
temperature goes up, the compressor will switch
on automatically.
The appliance needs at least 3 hours for the refrig-
erant to settle.
Lower the temperature regulator position.
Lower the temperature regulator position.
Turn the temperature regulator to a higher posi-
tion.
See "Checking and cleaning the door seals".
Only put food in that has already cooled down.
Never freeze more than 2.5 kg at a time.
Defrost the freezer compartment and check the
door seal.
Adjust the ambient temperature to climate catego-
ry "N" (+16 to +32 °C).
Humming – refrigeration unit is running.
Noise of a flowing liquid – refrigerant is flowing
though the pipes.
Clicking – the motor is switching on or off.
Check for stable position.
Remove any objects from the appliance.
Remove foreign objects from the rear.
GB