C
I
OMPLETING THE
NSTALLATION
Fixing the Outdoor Unit in Place
' X ' mm
Rubber leg
Model
X
2.12ft
36
(645mm)
Final Checks and Trial Operation
14
E-
You should install the outdoor unit on a stable base to avoid the generation
of noise and vibration, especially when installing the outdoor unit close to
your neighbor.
If you install the outdoor unit in a place exposed to strong winds or at a
height, you must fix it to the appropriate support (wall or ground).
1
Place the outdoor unit as indicated on the top of the unit to let the
discharged air out properly.
2
Fix the outdoor unit to the appropriate support using anchor bolts.
3
If the outdoor unit is exposed to strong winds, install shield plates around
the outdoor unit, so that the fan can operate correctly.
Y
1.12ft
Secure the rubber leg in order to prevent the generation of noise and
(340mm)
vibration.
To complete the installation, perform the following checks and tests to ensure
that the air conditioner operates correctly.
1
Check the following.
Strength of the installation site
Tightness of pipe connection to detect a gas leak
Electric wiring connection
Heat-resistant insulation of the pipe
Drainage
Earth conductor connection
Correct operation (follow the steps below)
2
Press the
The indicator on the indoor unit lights on and blinks.
The airflow blade opens and the fan gears up for operation.
3
Press any button and check the following.
T he appropriate indicator lights on and the air conditioner operates
according to the selected mode or function.
4
Press the
The airflow blades work properly.
button and check the following.
button and check the following.