Temco VFL34RN Installation And Operating Instructions Manual

Gas log heaters

Advertisement

Installation and Operating
Instructions for Gas Log
Heaters
Models: VFL34RN, VFL34RP
Models with "N" after the model number use natural gas; models with "P" after the model number use propane (LP) gas.
This appliance operates as an unvented room
heater certified under ANSI Z21.11.2-2000 when
fitted to a solid fuel burning masonry or factory
built fireplace with the flue damper closed. It also
operates as a decorative appliance under ANSI
Z21.60a-2000.CSA 2.26a-2000, when fitted to a solid
fuel burning masonry or factory built fireplace with
the flue damper open. When used as a decorative
appliance, the use of a thermostat is not allowed.
State or local codes may only allow operation of
this appliance in a vented configuration. Check
your state or local codes.
If the information in this manual is not followed exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or
any other appliance.
Do not try to light any appliance.
Do not touch any electric switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instruc-
tions.
If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or the gas
supplier.
This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisions
for adequate combustion and ventilation air must be provided. Refer to Section Provisions For Adequate
Combustion and Ventilation Air - Page 4.
5L24
READ AND SAVE THESE INSTRUCTIONS
WARNING
FOR YOUR SAFETY
WHAT TO DO IF YOU SMELL GAS
Gas Fired
Unvented
Room Heaters
Temco Fireplace Products
410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777
78570 11/03 Rev. 6

Advertisement

Table of Contents
loading

Summary of Contents for Temco VFL34RN

  • Page 1 Installation and Operating Instructions for Gas Log Heaters Models: VFL34RN, VFL34RP Models with “N” after the model number use natural gas; models with “P” after the model number use propane (LP) gas. READ AND SAVE THESE INSTRUCTIONS This appliance operates as an unvented room heater certified under ANSI Z21.11.2-2000 when...
  • Page 2: Table Of Contents

    Warranty Information ........................17 Installation and Startup Checklist ..................... 18 Warranty Registration ......................... 20 Minimum Dimensions for Existing Solid Fuel Burning Fireplaces Opening Height Front Width Rear Width Depth Hearth Size Table VFL34RN 17” 26” 21” 11” VFL34RP 17” 26” 21”...
  • Page 3: Important Information

    1/2 psig (3.5kpa). BTU/hr • DO NOT use this heater in recreational vehicles, bedrooms or Model Fuel bathrooms. VFL34RN Natural 34,000 22,000 • If this is the ONLY gas appliance, we recommend a VFL34RP LP/Propane...
  • Page 4: Provisions For Adequate Combustion Air

    Provisions for Adequate Combustion and Ventilation Air ________(volume of space) ÷ 50 cu. ft. = (Maximum BTU/ WARNING: This heater shall not be installed in a Hr the space can support. confined space or unusually tight construction unless Example: 5,000 cu. ft. (volume of space) ÷ 50 cu. ft. = 100 provisions are provided for adequate combustion or 100,000 (maximum BTU/Hr the space can support) ventilation air.
  • Page 5 Unusually tight construction is defined as construction If your home meets all of the three criteria above, you must where: provide additional fresh air. a. walls and ceilings exposed to the outside atmosphere have You may provide two permanent openings: one within 12" of a continuous water vapor retarder with a rating of one perm the ceiling and one within 12"...
  • Page 6: Installation

    Installation Unpacking However, it is recommended that these instructions be followed even when the appliance will be used as a vented decorative Open the carton and remove the logs and the chassis. Re- appliance in case local codes change to allow unvented space move each of the logs by gripping at either end of the log while heaters or in the event that the flue damper is inadvertently avoiding any undue pressure.
  • Page 7: Gas Connection

    No Canopy Used 10" 8" 27" 6" Min. 62" 23" Heat Resistant 1¹⁄₈" Min. Material 19" Min. 15" Min. 2" 10" Min. Fireplace Hearth Level Fireplace Opening Fig. 4A Minimum clearance to wall and ceiling. Fig. 4C Mantel clearances (single or multi-sided opening fireplaces).
  • Page 8: Typical Gas Line Connection

    Typical Gas Line Connection Step 1: With the engine assembly free from the fireplace, check tightness of flexible connector fittings. CAUTION: Use one wrench to hold regulator and one wrench to loosen and tighten the brass fittings. Failure to hold the regulator while loosening and tightening the fittings can damage the unit and cause gas leaks.
  • Page 9: Gas Line Pipe Sizing

    Gas Line Pipe Sizing NOTE: To determine the size of the branch gas line from the main gas line to the fireplace, enter the tables below (for iron pipe or copper tubing) using the distance from the gas meter or second stage regulator to the furthest appliance on the gas system.
  • Page 10: Log Assembly

    Left Twig your unit. Do not use embers other than genuine “Platinum Front Log TL106 Embers” supplied by Temco Fireplace Products - Part No. 78037. Fig. 7 Correct log placement. When you have completed these steps, compare log positions with Figure 7. The logs must be positioned as illustrated.
  • Page 11: Millivolt System Control Options

    Millivolt System Control Options Burner ON/OFF Control Recommended Maximum Lead Length (Double Wire) Several options are available to turn the burner ON/OFF. These When Using Wall Switch or Thermostat options include: WRD-1 standard ON/OFF remote, WRST-K thermostatically controlled remote, WSW Millivolt wall switch or Wire Size Maximum Length GFPMT Millivolt wall thermostat.
  • Page 12: Lighting Instructions

    For Your Safety, Read Before Lighting WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. •...
  • Page 13: Important Safeguards

    Typical flame shape seen in Figure 18. Propane Natural Gas 1¹⁄₂" 1¹⁄₂" TL108 Fig. 18 Correct burner flame appearance. Air Shutter Settings Model T122 VFL34RN Closed VFL34RP 0.375” Fig. 17 Pilot flame position and location. T134 Fig. 19 Air shutter settings. 78570...
  • Page 14: Managing Heat Output

    Managing Heat Output The heat output from the appliance can be controlled by the Whenever the appliance is operated with the fireplace's position of the flue damper on vented fireplaces. flue damper closed, glass doors - if present - must be open and the outside air damper and the ash dump (if the The damper setting should be fully closed for maximum heat fireplace is equipped with either one) must be closed.
  • Page 15: Troubleshooting

    Troubleshooting diagnosis of problems and the corrective action to be taken. With proper installation and maintenance, your new gas fireplace should provide years of trouble-free service. If you do Any safety screen or guard removed for servicing an appliance experience a problem, refer to the trouble shooting guide below. must be replaced prior to operating the appliance.
  • Page 16: Repair Parts

    Repair Parts Always include the correct name, part number, model number, Temco Fireplace Products control type and serial number of the appliance when ordering 410 Admiral Blvd. service parts. Refer to the parts list below. Mississauga, Ontario Use manufacturer's authorized parts only. If you desire to...
  • Page 17: Warranty Information

    TEMCO, any component covered Pages 18 and 19 of this manual. under this warranty is found to be defective, TEMCO will, The limited warranty applies only to the original owner of at its option, repair or replace the defective component at...
  • Page 18: Installation And Startup Checklist

    INSTALLATION AND STARTUP CHECKLIST Customer Copy NOTE: TEMCO Fireplace Products gas logs and fireplaces require installation by a qualified gas appliance installer. A copy of this checklist must be submitted, along with proof of purchase, when applying to Technical Services for prior written approval of warranty repair or replacement.
  • Page 19 INSTALLATION AND STARTUP CHECKLIST Installer’s Copy NOTE: TEMCO Fireplace Products gas logs and fireplaces require installation by a qualified gas appliance installer. A copy of this checklist must be submitted, along with proof of purchase, when applying to Technical Services for prior written approval of warranty repair or replacement.
  • Page 20: Warranty Registration

    Mississauga, Ontario Canada L5T 2N6 Serial # ______________________________________ Model # ______________________________________ I certify that I have followed all codes and regulations and adhered to the TEMCO installation instructions. I have completed the proper installation and startup checklist. Installer’s Signature Print Installer’s Name...

This manual is also suitable for:

Vfl34rpVfl34mnVfl34mp

Table of Contents