Technical Data - Rinnai RHFE-263FA Owner's Operation And Installation Manual

Energysaver gas direct vent wall furnace
Hide thumbs Also See for RHFE-263FA:
Table of Contents

Advertisement

WEIGHT
DIMENSIONS
Width: 16 3/4"
37.5 Lbs.
Height: 26 5/8"
Depth: 9 13/16"
Burner Orifices:
RHFE-263FA-P use: Orifice part #AU129-210 02-0.90(0.035")
RHFE-263FA-N use: Orifice part #AU129-210 02-1.30(0.051")
GAS
MODEL
TYPE
RHFE-263FA
NG
RHFE-263FA
LPG
GAS SUPPLY PRESSURE
NATURAL
MINIMUM
3.5"W.C.
MAXIMUM
10.5"W.C.
The minimum inlet gas supply pressures are for the purpose of input adjustment.
Heaters may be converted from one gas to another using Rinnai conversion kits.

TECHNICAL DATA

LOW
HIGH
11,000 11,000
GAS CONVERSION SPECIFICATIONS
DIAMETER OF
PRIMARY
ORIFICE(mm)
DAMPER
308F-209-13
1.30
308F-209-7
0.90
PROPANE
8.0"W.C.
13.0"W.C.
GAS RATE (BTU/h)
INPUT
NG
LP
5,500
5,700
LOW
HIGH
MANIFOLD DIFFERENTIAL
SECONDARY
PRESSURE (W.C.)
DAMPER
308F-218-1
( 3.0 10)
308F-218-3
( 2.5 10)
– 52 –
OUTPUT
NG
LP
4,450
4,600
8,800
8,800
HI
LO
2.3"W.C.
0.6"W.C.
3.7"W.C.
1.1"W.C.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents