Download Print this page

Technical Data - Rinnai RHFE-1004FA Conversion Manual

Energysaver gas direct vent wall furnace

Advertisement

Available languages

Available languages

CONVERSION MANUAL : RHFE-1004FA
WEIGHT
90 Lbs.
HI
1004F-2031-B-1.80
LOW
1004F-2036-B-1.95
MODEL
RHFE-1004FA-P
(Normal Altitude)
RHFE-1004FA-P
(High Altitude)
RHFE-1004FA-N
(Normal Altitude)
RHFE-1004FA-N
(High Altitude)
MINIMUM
5.0"W.C.
MAXIMUM
10.5"W.C.
• The minimum inlet gas supply pressures is for the purpose of input adjustment.
• Heaters may be converted from one gas to another using Rinnai conversion kits.
• Output efficiency is 80% of rated input for Canadian installations.
The conversion shall be carried out in accordance with the requirements of provincial authorities having jurisdiction
and in accordance with the requirements of the CAN1-B149.1 and 2 installation code. The appliance shall only be
converted to a gas for which it has been approved. Conversion kit shall be installed by a qualified service agency.
Front panel must be removed to access internal parts. Conversion kit are included in the carton box. Caution the gas
supply shall be shut off prior to disconnecting the electrical power, before proceeding with the conversion. Locate
orifices at burner end of gas tubes.
This conversion kit shall be installed by a qualified service agency in accordance with the manufacture's instructions
and appliance codes and requirement of the authority having jurisdiction. If the information in these instructions is not
followed exactly, a fire, explosion or production of carbon monoxide may result causing property damage, personal
injury or loss of life. The qualified service agency is responsible for the proper installation of this kit. The installation
is not proper and complete until the operation of the converted appliance is checked as specified in the
manufacture's instructions supplied with the kit.

TECHNICAL DATA

DIMENSIONS
Width: 36 5/8"
Height:26 3/8"
Depth: 12 3/8"
LOW
HIGH
BURNER ORIFICES
NAT.
PARTS No.
QTY'
2
1
GAS CONVERSION SPECIFICATIONS
DIAMETER OF
ORIFICES
GAS
INCHES (mm)
TYPE
HI
LOW
0.037
0.047
LPG
(0.95)
(1.20)
0.071
0.077
NAT.
(1.80)
(1.95)
GAS SUPPLY PRESSURE
NAT.
LPG
11.0"W.C.
13.0"W.C.
RHFE-1004FA ENERGYSAVER CONVERSION
GAS RATE (BTU/h)
INPUT
NAT.
LPG
10,500 10,500
LOW
38,400 36,500
HIGH
LPG
PARTS No.
1004F-2031-A-0.95
1004F-2036-A-1.20
DAMPER
ADJUSTMENT
FRONT
RIGHT
LEFT
10/10
10/10
10/10
7/10
10/10
10/10
"WARNING"
– 1 –
NAT.GAS to LPGAS
LPGAS to NAT.GAS
OUTPUT
NAT.
LPG
8,400
8,400
30,720 29,200
QTY'
2
1
MANIFOLD
DIFFERENTIAL
PRESSURE
HI
LOW
10.1"W.C.
4.3"W.C.
7.3"W.C.
4.3"W.C.
3.7"W.C.
2.0"W.C.
2.7"W.C.
2.0"W.C.

Advertisement