Service Test Program - Philips FW-C355 Service Manual

Hide thumbs Also See for FW-C355:
Table of Contents

Advertisement

SERVICE TEST PROGRAM

TUNER
QUARTZ
TEST
TEST
N
TUNER
Button pressed?
Y
Display Tuner Version
"ccc"
N
TUNER
Button pressed?
Y
Service frequencies are
copied to the RAM (see Table1)
Tuner works normally
except:
PROGRAM button
pin 80 of uP = 1,953.125Hz
N
Disconnect
Mains cord ?
Y
Service Mode left
Note: During the 3CDC tray may "jerks" open
& close or the carousel may rotates
slightly. This is due to sharing of control
lines during the Service test program.
East Eur. Extended-band
Europe
East Eur.
PRESET
"EUR"
"EAS"
"EAS"
1
87.5MHz
65.81MHz
87.5MHz
108MHz
2
108MHz
108MHz
3
531kHz
74MHz
531kHz
87.5MHz
4
1602kHz
1602kHz
5
558kHz
531kHz
558kHz
1602kHz
6
1494kHz
1494kHz
7
87.5MHz
558kHz
87.5MHz
8
87.5MHz
1494kHz
87.5MHz
98MHz
9
87.5MHz
87.5MHz
10
87.5MHz
70.01MHz
87.5MHz
65.81MHz
11
98MHz
98MHz
Table 1
Note: * Depending on the selected grid frequency (9 or 10kHz)
By holding the TUNER and R buttons depressed while switching on the Mains supply, one
of the undermentioned features will be activated:
- the tuning grid frequency is toggled between 9kHz and 10kHz for the Oversea (/21) version.
- the extended FM1 (65.81MHz - 74MHz) is toggled on and off for East Eur. (/34) version.
3-1
To start service test program
hold P & TAPE
depressed while
plugging in the mains cord
S refers to Service Mode.
Display shows the
ROM version *
V refers to Version.
"S-Vyy"
(Main menu)
yy refers to Software version number of Processor.
(Counting up from 01 to 99)
N
O
STANDBY-ON
Button pressed?
Button pressed?
Y
Y
Display shows
Set is in Service PLAY Mode.
32K
Output at (Front Board)
In case of failures, error
pin 80 of uP = 2048Hz
codes according to table 2
will be displayed.
The Service Play Mode is intended to
O
N
detect and identify the failures in the CD Mode.
Button pressed?
In this mode the electronics will still function
even when an error is detected so that
repair activities can be carried out.
Y
Display shows
8M
Output at (Front Board)
9
N
Error code
Button pressed?
E1000
Y
E1001
E1002
USA
Oversea
"USA"
"OSE"
E1003
87.5MHz
87.5MHz
108MHz
108MHz
E1005
530kHz
530/531kHz*
1700kHz
1700/1602kHz*
E1006
560kHz
560/558kHz*
1500kHz
1500/1494kHz*
E1007
98MHz
98/87.5MHz*
87.5MHz
87.5MHz
E1008
87.5MHz
87.5MHz
87.5MHz
87.5MHz
E1020
87.5MHz
87.5/98MHz*
E1070
E1071
E1079
SERVICE
PLAY MODE
N
note 1 :
JAZZ & TECHNO are on while OPTIMAL is off, other LEDs status
are not important (applicable only for sets with LEDs)
Figure 1
note 2 :
OPTIMAL is on while JAZZ & TECHNO are off, other LEDs status
are not important (applicable only for sets with LEDs)
Figure 2
Error Description
Focus Error
Triggered when the focus could not be found within a certain time when starting up the CD
or when the focus is lost for a certain time during play.
Radial Error
Triggered when the radial servo is off-track for a certain time during play.
Sledge In Error
The sledge did not reach its inner position (inner-switch is still close) before approximately
6 Sec. have passed by. Inner-switch or sledge motor problem.
Sledge Out Error
The sledge did not come out of its inner position (inner-switch is still open) before approximately
250 mSec. have passed by. Inner-switch or sledge motor problem.
Jump-offtrack error
Triggered in normal play when the jump destination could not be found within a certain time.
When this error occurred, software will try to recover by initiating the jump command again.
If it is recoverable, the disc will continue to play.
Subcode Error
Triggered when a new subcode was missing for a certain time during play.
PLL Error
The Phase Lock Loop could not lock within a certain time.
Turntable Motor Error
Generated when the CD could not reached 75% of speed during startup within a certain time.
Discmotor problem.
Focus Search Error
The focus point has not been found within a certain time.
This happens when the carousel switch is defective and closed all the time, or when the
carousel is blocked when it is located exactly at a disc position.
This happens when the carousel switch is defective and does not closed electrically, or when
the carousel is blocked in between two disc positions. The time-out is approximately 5 Sec.
The drawer could not open or enter the inside position and is opening again. This happen when
the drawer is blocked and cannot go fully inside or when the drawer switch is defective and does
not close.
Table 2
3-1
Mini 2002 FW-C1xx, C2xx, C3xx Dated: wk141
DISPLAY
TEST
N
DIM
Button pressed?
Y
Display shows Fig. 1
and selected LEDs on
(see note 1)
N
DIM
Button pressed?
Y
Display shows Fig. 2
and selected LEDs on
(see note 2)
9
N
Button pressed?
Y
Various
other Tests
TEST
Activated with
ACTION
R
EEPROM TEST
A test pattern will be sent to the EEPROM.
"PASS" is displayed if the uProcessor read
back the test pattern correctly, otherwise
"FAIL" will be displayed.
9 to Exit
Q
EEPROM FORMAT
Load default data. Display shows "NEW"
for 1 second.
Caution!
All presets from the customer will be lost!!
ROTARY
Volume Knob
Display shows value for 2 seconds.
ENCODER TEST
or
Values increases or decreases in steps of 1
Jog Shuttle knob
until 0 (Min.) or 40 (Max.) is reached.
DEMO
DBB
DEMO will toggle on or off.
The message: "DEMO ON" or "DEMO OFF"
will scroll across the display to show the
new status of the set.
Disconnect
LEAVE SERVICE
mains cord
TESTPROGRAM

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents