(3) Control Settings

Power Switch
.............................................. ON
Fader Control
........................... Center Position
Balance Control
....................... Center Position
Treble Control
.......................... Center Position
Bass Contro
............................. Center Position
MX
................................................... Non Effect
(4) Adjustment Procedures
Connection
Step
Description
Signal Meter
Auto
Figure 3
1
Adjustment
(FM)
Det Out-DC
OFFSET
2
Figure 3
Adjustment
(FM)
Signal Meter
Auto
3
Figure 4
Adjustment
(MW)
Signal Generator
Dial Control
87.5MHz,
(1)
26dBµ
87.5MHz
(Mod. OFF)
87.5MHz,
(2)
26dBµ
87.5MHz
(Mod. OFF)
87.5MHz,
21~23dBµ
87.5MHz
(3)
(Mod. OFF)
87.5MHz,
(4)
26dBµ
87.5MHz
(Mod. OFF)
87.5MHz,
26dBµ
87.5MHz
(1)
(Mod. OFF)
87.5MHz,
26
-20dB
µ
(2)
87.5MHz
(Mod. OFF)
87.5MHz,
(3)
-20dBµ
87.5MHz
(Mod. OFF)
999kHz,
999kHz
(1)
34dBµ
(Mod. OFF)
999kHz,
999kHz
(2)
34dBµ
(Mod. OFF)
999kHz,
999kHz
(3)
29~31dBµ
(Mod. OFF)
999kHz,
µ
999kHz
(4)
34dB
(Mod. OFF)
- 9 -
Band Switch
.............................. FM/MW/LW
T-CORR
...................................... Non Effect
EQ
....................................................... FLAT
DEMO
................................................... OFF
Others
................................................... OFF
Test Point /
P.W.Board
Coordinates
TP002
Auto Adjustment:
(3-F)
After setting up of Signal Genarator,
TP501
short GND and TP501 (Pull-Down)
(3-F)
for 2~3 seconds.
Proceed same Auto Adjustment of step
(1) under step (2).
TP002
(SPEC) TP002 : 1.5±0.1V
(3-F)
(SPEC) TP002 : others 1.5±0.1V
TP501
NOTE : NG : Proceed same Auto
(3-F)
TP002
(3-F)
Proceed same Auto Adjustment of step
TP501
(1) under step (3).
(3-F)
TP002
(3-F)
Proceed same Auto Adjustment of step
TP501
(1) under step (4).
(3-F)
" DC OFFSET " displays after finishing
S-METER (FM) adjustment.
The SIGNAL GENERATOR output of
26dBu is lowered to -20dBu within
10 seconds.
When adjustment is finished,the
" DC OFFSET " display disappears.
Auto Adjustment:
TP002
(3-F)
After setting up of Signal Genarator,
short GND and TP501 (Pull-Down)
TP501
for 2~3 seconds.
(3-F)
Proceed same Auto Adjustment of step
(1) under step (2).
TP002
(SPEC) TP002 : 1.0±0.1V
(SPEC) TP002 : others 1.0±0.1V
(3-F)
TP501
(3-F)
NOTE NG : Proceed same Auto
TP002
Proceed same Auto Adjustment of step
(3-F)
(1) under step (3).
TP501
(3-F)
TP002
Proceed same Auto Adjustment of step
(3-F)
(1) under step (4).
TP501
(3-F)
CDA-9855R
Adjustment
OK
NG
Adjustment of step (1)
under step (3).
OK
NG
:
Adjustment of step (1)
under step (3).
TO CONTENTS