INSTALLATION INSTRUCTIONS
Assembly and electrical connections must be carried out by specialized personnel.
• Electric Connection
The appliance has been manufactured as a class I, therefore earth cable is necessary.
The connection to the mains is carried out as follows:
If not provided, connect a plug for the electrical load indicated on the description label.
Where a plug is provided, the cooker hood must be installed in order that the plug is easily
accessible.
An omnipolar switch with a minimum aperture of 3mm between contacts, in line with the
electrical load and local standards, must be placed between the appliance and the network
in the case of direct connection to the electrical network.
• The minimum distance between the support surfaces of the cooking pots on the cooker
top and the lowest part of the cooker hood must be at least 65 cm. If a connection tube
composed of two parts is used, the upper part must be placed outside the lower part.
Do not connect the cooker hood exhaust to the same conductor used to circulate hot air or
for evacuating fumes from other appliances generated by other than an electrical source.
Before proceeding with the assembly operations, remove the anti-grease filter(s) (Fig.5) so
that the unit is easier to handle.
In the case of assembly of the appliance in the suction version prepare the hole for
evacuation of the air.
FIXING TO THE WALL
?
Drill the holes A respecting the distances indicated (Fig.2).
Fix the appliance to the wall and align it in horizontal position to the wall units. When the
appliance has been adjusted, definitely fix the hood using the screws A.
For the various installations use screws and screw anchors suited to the type of wall (e.g.
reinforced concrete, plasterboard, etc.). If the screws and screw anchors are provided with
the product check that they are suitable for the type of wall on which the hood is to be
fixed.
FIXING THE DECORATIVE TELESCOPIC FLUE
?
Arrange the electrical power supply within the dimensions of the decorative flue. If your
appliance is to be installed in the ducting version, prepare the air exhaust opening. Adjust
the width of the support bracket of the upper flue (Fig.3). Then fix it to the ceiling using the
screws A (Fig.2) in such a way that it is in line with your hood and respecting the distance
from the ceiling indicated in Fig.2. Connect the flange C to the air exhaust hole using a
connection pipe (Fig.4).
L=live
N=neutral
E=earth
IEC227
Brown
Blue
Green/Yellow