5.2 Understanding Error Codes

When an error code appears on the front panel, refer to the following chart for a definition and possible remedy for the situation.
Error Code
Reason
E003
Ignition failure
E004
False flame detection
E012
Flame loss
E016
Overheating of heat exchanger
Exhaust overheating (the water heater shuts
E030
down when the flue temperature exceeds
149°F (65°C)
E046
Abnormal operation: limit control
E047
Abnormal operation: exhaust thermostat
E060
Abnormal operation: dual venturi
E109
Abnormal operation: fan motor
E110
Abnormal air pressure
Hot water outlet: thermistor open or short
E407
circuit
Cold water inlet1: thermistor open or short
E421
circuit
Cold water inlet2: thermistor open or short
E432
circuit
E434
Abnormal operation: water adjustment valve
E438
Abnormal operation: circulation pump
E439
Abnormal operation: flow sensor
Hot water inlet2: thermistor open or short
E441
circuit
E445
Abnormal operation: Bypass mixing valve
E515
Abnormal operation: PCB
E517
Abnormal operation: DIP switch setting
E593
Abnormal operation: front panel key
E615
Abnormal operation: input and memory
E736
Abnormal operation: cascade communication
E760
Flushing/service alarm
Abnormal operation: main panel
E782
communication
If any of these remedies do not resolve the problem, contact Technical Support at 1-800-519-8794.
16
Troubleshooting
Self-diagnostic / Action
Ensure that the main gas supply valve is open.
Ensure that the electrical cord is properly grounded.
Clean the intake air filter. See page
Ensure that the electrical cord is properly grounded.
Turn off the system for at least 30 minutes, and then restart it.
Clean the cold water inlet filter. See page
Flush the heat exchanger. See page
Turn off the system for at least 30 minutes, and then restart it.
Clean the cold water inlet filter. See page
Flush the heat exchanger. See page
Contact Technical Support at 1-800-519-8794.
Contact Technical Support at 1-800-519-8794.
Contact Technical Support at 1-800-519-8794.
Clean the intake air filter. See page 13.
Ensure that the exhaust pipe is free of obstructions.
Clean the intake air filter. See page
Contact Technical Support at 1-800-519-8794.
Contact Technical Support at 1-800-519-8794.
Contact Technical Support at 1-800-519-8794.
Contact Technical Support at 1-800-519-8794.
External: Ensure that all water supply and return lines are open.
Internal: Check the direction of the 2-way valve.
Contact Technical Support at 1-800-519-8794.
Contact Technical Support at 1-800-519-8794.
Contact Technical Support at 1-800-519-8794.
Ensure that the electrical cord is properly grounded.
Contact Technical Support at 1-800-519-8794.
Contact Technical Support at 1-800-519-8794.
Contact Technical Support at 1-800-519-8794.
Contact Technical Support at 1-800-519-8794.
Contact the installer to perform routine service.
Contact Technical Support at 1-800-519-8794.
13.
12.
11.
12.
11.
13.