Download Print this page
onga  Owner's Manual

onga Owner's Manual

Leisure time pool pumps

Advertisement

Leisure Time
Pool Pumps
The pump must be supplied through a Residual Current
Devise (RCD) having a rated residual operating current not
exceeding 30mA.
Should you the installer or owner be unfamiliar with the correct
installation or operation of this type of equipment you should contact
the distributor/manufacturer for the correct advice before proceeding
with the installation or operation of the product.

Advertisement

loading

Summary of Contents for onga Onga

  • Page 1 Leisure Time Pool Pumps The pump must be supplied through a Residual Current Devise (RCD) having a rated residual operating current not exceeding 30mA. Should you the installer or owner be unfamiliar with the correct installation or operation of this type of equipment you should contact the distributor/manufacturer for the correct advice before proceeding with the installation or operation of the product.
  • Page 2 Relax - you’ve bought an Congratulations on your decision to purchase an Onga product. Onga is one of the best know brands in its field, with a proud local and international reputation. Onga is a brand for reliability, value for money and technological innovation.
  • Page 3 ISO 9001:2008 accreditation. A Fair Price Onga products are neither the cheapest nor the most expensive in their field. Our products do, on the other hand, always represent very good value for money; they always have and they always will.
  • Page 4: Table Of Contents

    Table of Contents Page Safety Installation Operation Service & Maintenance Removal of Pump for Servicing Parts Diagram Troubleshooting...
  • Page 5: Safety

    Safety IMPORTANT! The operator must be provided with this owner’s manual. This must be read before operation and followed during operation. These instructions are a guide only. Users not familiar with pool equipment should seek advice from suitably qualified persons with experience in pool equipment installation. Models: LTP400, LTP550, LTP750, LTP1100 (3/4hp) (1hp)
  • Page 6 Installation Pump Discharge/Outlet Pump Discharge/Outlet The fittings on these pool pumps are constructed of ABS. Some PVC jointing compounds are incompatible with ABS possibly causing failure to the product. Check compound suitability prior to use. All glued fittings and pipe work should be allowed to dry to atmosphere for 24 hours before closing installation.
  • Page 7: Installation

    Installation 6) Protect from excess moisture, vermin, dust and weather. 7) Allow access for servicing pump and piping. 8) To provide adequate ventilation keep rear of motor clear (100mm Min) 9) Do not use electrical extension cords/leads. Points of Note a) The pump is to be supplied through a residential current device (RCD) having a rated residual operating current not exceeding 30mA b) This appliance is not intended for use by persons (including children) with reduced...
  • Page 8: Operation

    Operation Priming Pump: a) In a flooded suction system (water source higher than pump), the pump will fill itself with water when suction and discharge valves are opened. Water will be at the top of the hair and lint pot lid. b) If pump is not in a flooded suction system, unscrew and remove hair and lint pot lid;...
  • Page 9: Service & Maintenance

    This indicates a leaking mechanical seal. Failure to fix this may result in premature product failure. NOTE: Onga recommend the use of silicon based lubricant on all ‘O’rings. The only routine maintenance needed is inspection/cleaning of leaf basket. Debris or trash that collects in basket will choke off water flow through the pump. Follow...
  • Page 10: Removal Of Pump For Servicing

    Remove pump and take to your nearest authorised Onga service agent or call: 1800 664 266 (Australia) 0800 664 269 (New Zealand) If the need arises to contact an Onga service agent please have all details available including model and serial number, date of purchase and particulars of fault.
  • Page 12: Troubleshooting

    Trouble Shooting Guide SYMPTOM CAUSE REMEDY Pump does not Run No Power at the power outlet Use another electrical appliance that is known to work to check the power point. Blown Fuse. Check Fuse and replace if necessary Automatic Thermal Overload has Switch the power to the pump off tripped to protect the motor.
  • Page 13: Trouble Shooting Guide

    Check alignment and Mechanical Seal needs replacing condition of casing ‘O’ring before re-tightening. Replace the ‘O’ring if leaking persists. Replace the mechanical seal and lip seal if fitted. -Should problems persist please contact your nearest Onga service agent.
  • Page 14 Phone: +61 3 9709 5800 Fax: +61 3 9709 5888 © Information contained here-in remains the property of Pentair Water Pty Ltd. Any reproduction, display, publication, modification or distribution is strictly prohibited without the prior written permission of Pentair Water Pty Ltd.

This manual is also suitable for:

Ltp400Ltp550Ltp750Ltp1100