Download Print this page

Command Summary - Wenshing RS232 Hi Power Instruction Manual

Wireless rs232 high power transceiver (2w)

Advertisement

Command Summary

COMMAND
0x80
0x80
(Product info)
0x81
(Set RF
0x81+1 byte
transmission
(0x00~07)
rate )
0x83
0x83+1 byte
(Set ID)
(0x00~FF)
0x84
0x84+1 byte
(Set power
(0x00~14)
consumption)
0x85
0x85+1 byte
(Set RS232 rate)
(0x00~07)
0x86
0x86+1 byte
(Set link mode)
(0x00 or 0x01)
0x87
0x87+2 bytes
(Set group ID)
(0x0000~FFFF)
0x8D
0x8D+72 bytes
(Detect interface
(Only 0x8D)
rate)
0x8F
0x8F+72 bytes
(Cancel transfer
(Only 0x8F)
station)
0xC0
0xC0+1~11
(Preset transfer
bytes
station)
(0x00~FF)
Please use COM Demo program which WENSHING opened to send Hex code
which format command is 16bytes and amend to RS232 Hi Power.(Initial setting
for interface rate is 115200bps.) When user amended success, RS232 Hi Power
will automatically reply parameters for user's confirmation. After successful
setting, user can begin to use.
http://www.wenshing.com.tw; http://www.rf.net.tw
Send Value
TRW-909V100
Correct setting will return
send value; incorrect setting
will have no back value.
Correct setting will return
send value; incorrect setting
will have no back value.
Correct setting will return
send value; incorrect setting
will have no back value.
Correct setting will return
send value; incorrect setting
will have no back value.
Correct setting will return
send value; incorrect setting
will have no back value.
Correct setting will return
send value; incorrect setting
will have no back value.
Correct setting will return
send value; incorrect setting
will have no back value.
Correct setting will return
send value; incorrect setting
will have no back value.
Correct setting will return
send value; incorrect setting
will have no back value.
Back Value
RS232 Hi Power Data Sheet P.5
Remark
1 byte setting,
default value is 0x07.
1 byte setting,
default value is 0x00.
1 byte setting,
default value is
0x07=100mW.
1 byte setting,
default value is
0x07=115200bps.
1 byte setting,
default value is
0x01=RS232 Modem.
2 bytes setting,
default value is 0x0000.
Repeat 0x8D and total
are 72 bytes, repeat
sending
and
switch
interface rate until it
return send value.
Repeat 0x8F and total
are 72 bytes,
if you
received
return
send
value after sent value, it
is meaning you already
cancel transfer station.
Min: 1 byte,
Max: 10 bytes.

Advertisement