Wireless RS232 High Power Transceiver (2W) Instruction Manual Revision History Version Date Changes V1.02 Mar. 2, 2009 First Edition V1.03 May. 23, 2009 Second Edition V1.04 Jun. 02, 2009 Third Edition V1.05 Jun. 04, 2009 Forth Edition http://www.wenshing.com.tw; http://www.rf.net.tw RS232 Hi Power Data Sheet P.1...
2W Peak Sleep Mode RF Characteristic Frequency Range Data Rate Kbps GFSK TX Output Power RX Sensitivity -118 Modulation GFSK Other 2000 Interface Data Rate 115.2 Kbps Dimension 74.9 x 25.6 x 25.6 http://www.wenshing.com.tw; http://www.rf.net.tw RS232 Hi Power Data Sheet P.2...
Please use COM Demo program which WENSHING opened to send Hex code which format command is 16bytes and amend to RS232 Hi Power.(Initial setting for interface rate is 115200bps.) When user amended success, RS232 Hi Power will automatically reply parameters for user’s confirmation.
Page 6
Set RS232 interface transmission rate: you can collocate with equipment rate. Set group ID: GID is for working group identify. When GID are different, equipments can ‘t send data or receive data each other. http://www.wenshing.com.tw; http://www.rf.net.tw RS232 Hi Power Data Sheet P.6...
Page 7
If you want to send data 9999 from equipment which UIP=01 through equipment which UID=03 to transfer to equipment which UID=04, data format which you send is 0x7203049999. GID:D391 Transfer UID:03 GID:D391 GID:D391 UID:01 UID:04 Send=7203049999 Receive=9999 GID:D391 UID:02 http://www.wenshing.com.tw; http://www.rf.net.tw RS232 Hi Power Data Sheet P.7...
Page 9
Set power consumption : user can amend power consumption through command according to different application. Available set rage is from 3mW to 2W and default value is 100mW. Address Read/Write Byte Default(Hex) Range(Hex) 0x84 00~15 Output Power Set Value 14.5 17.5 http://www.wenshing.com.tw; http://www.rf.net.tw RS232 Hi Power Data Sheet P.9...
Page 10
0x02 0x03 0x04 0x05 0x06 0x07 Set link mode: RS232 Hi Power can collocate with RD-800HI and 3C message receive device. User can amend the link mode through command according to the product which you allocate with. Address Read/Write Byte...
Page 11
Maximum transfer stations you can set are 10. Setting way is to add UID number on finial receiver side behind the command. If you need to go through transfer station, you need to insert UID number of path in the middle. http://www.wenshing.com.tw; http://www.rf.net.tw RS232 Hi Power Data Sheet P.11...
Page 12
UID:02 Or , command is 0xC00204 when UID=01→UID=02→UID=04 GID:D391 UID:03 GID:D391 GID:D391 UID:01 UID:04 GID:D391 UID:02 Method 2: command is 0xC0020304 when UID=01→UID=02→UID=03→UID=04 GID:D391 UID:03 GID:D391 GID:D391 UID:01 UID:04 GID:D391 UID:02 http://www.wenshing.com.tw; http://www.rf.net.tw RS232 Hi Power Data Sheet P.12...
Page 13