Operation; Bargraph Scales - BEL BG-8 User Manual

8 channel digital audio monitor
Table of Contents

Advertisement

BEL DIGITAL AUDIO
O
p
e
r
a
t
O
p
e
r
a
t
Once the BG-8 Digital Audio (AES) monitor is configured for the required meter type and
coloured transition point, it is ready to be used to monitor up to four pairs of AES audio. Lock
LEDs show if the sample rate of the incoming audio is locked for each AES pair.
The coloured bargraph areas can be configured to show normal level, under level and over
level to assist operation. Each group of four channels can be configured independently for
different meter types, scales and coloured level transition points.

Bargraph scales

The following meter types may be selected using switches at the rear of the unit.
Scale type
Range
AES/EBU:
60dB (0 to -60dB)
DIN PPM:
55dB (+5 to -50dB)
VU:
23dB (+3 to -20dB)
BBC PPM:
+12 to-12dB - mark 7 to 1
NORDIC:
54dB (+12 to -42dB)
IEC:
29dB (+9 to -20dB)
Note: Refer to the Installation chapter for bargraph settings and graticule/scale fitting
instructions.
 2006 BEL (Digital Audio) Ltd
i
o
n
i
o
n
The BG-8 front panel
BG-8 meter types
BG-8
Attack
Fallback
1ms
1.5Sec per 20dB decay
10mSec
1.5Sec per 20dB decay
300mSec
300mSec
10mSec
2.85Sec - mark 7 to 1
5mSec
1.7Sec per 20dB decay
5mSec
1.7Sec per 20dB decay