GE PTAN9150MWW Technical Service Manual page 19

Top load washer
Table of Contents

Advertisement

Wash Cycle Progression (cont.)
Level
detection/
Overload
sensing
Clothes
arrangement
Fill to Minimum
Water Level
(Sensing Level)
Takes 2 spins, measures time to reach a certain angle.
Estimates if load is greater than 17 lbs or not.
If load is greater than 17lbs, it bypasses the "load arrange-
ment" phase and goes straight to the pre-fill portion.
Washer executes pattern to distribute the clothes previous to
agitation in order to improve wash performance.
Load spins 2 times (CCW-CW), each time injecting cold water for 8
seconds.
• During each spin portion, the motor is successively activated (for
600 ms) and deactivated (for 2 seconds), intermittently spinning the
basket for a total of approx 10 seconds.
• Once the 10 seconds are over, unit goes into a full spin (at 700
RPM) and drain pump is activated for 10 seconds.
•After this, unit slows down to 100RPM.
Water and detergent are admitted in this stage
directly into the basket.
• Water fill starts until the minimum water level is
reached.
• Water is at temp selected by consumer, regulated
by ATC thermistor.
19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ptan9250mwsPtan9350mwsPtan9450mwsPtan9455mgg

Table of Contents