stitution will void the agencies' certifications and the
Norcold warranty. Refer to this manual for proper in-
structions. Install the refrigerator and vents as directed
by Norcold without modification.
The clearance from the refri g erator's left side ( facin g
the front of the refri g erator ) to the vehicle's exterior wall
is important. This is the area in which the inlet and outlet
flexible pipin g will be connected to the vent terminal
housin g durin g installation. Refer to Figures 3 and 4 for
maximum clearances from refrigerator cabinet to vehi-
cle exterior wall.
The wall thickness the vent terminal housin g will
accommodate is .030" minimum to 1.250" maximum.
Fi g ure 2 illustrates the confi g uration of the openin g for
the vent terminal housin g . Do not make the opening in
the vehicle wall larger than required. The clearance
should be enou g h for the terminal housin g to pass
throu g h the openin g . If the openin g is too lar g e, the
outer g asket will not cover the vent housin g openin g .
Fi g ure 2 - Air Intake/Exhaust Assembl y
1. Mountin g Screw
2. Vent Cover
3. Outer Disk
4. Inner Disk
5. Rubber Gasket
6. Vent Terminal
Housin g Cut-Out
7. Vent Terminal
Housin g
It is imperative that the wall openin g for the vent
terminal housin g not be too low. The flexible pipin g
( inlet and outlet pipes ) must rise from the refri g erator to
the terminal housin g . There are two specific vent-air
intake assembl y kits available to accommodate most
installations. Figures 3 and 4 illustrate two installations
with the maximum flexible piping lengths and the vent
terminal housing locations.
8. O Rin g s
9. Intake Pipin g
10. Exhaust Pipin g
11. Lockin g Washer Screw
12. Lockin g Washer
13. Vehicle Exterior Wall
14. Mountin g Screw
15. Mountin g Screw
Intake Pipe
max. len g th
16"
Exhaust Pipe
max. len g th
14"
Fi g ure 3 - Kit #617941 Flexible Pipin g & Vent Location
Intake Pipe
max. len g th
21 3/4"
Exhaust Pipe
max. len g th
19 3/4"
Fi g ure 4 - Kit #617943 Flexible Pipin g & Vent Location