APPENDICES • APPENDIX B: PINOUTS
Pin
1
2
3
4
5
6
7
8
9
Use twisted pair cable for the connections indicated below.
TS612 Mainframe (DB15M)
Description
Pin
1
2
3
4
5
6
7
8
9
10
11-14
15
TECHNICAL SUPPORT: 1.800.283.5936 (USA) OR 1.801.974.3760
Description
Start
No Connection
No Connection
Stop
Record Enable
Tape Start Com
No Connection
Tape Stop Com
Record Enable Com
Serial TX -
Serial TX +
Serial RX -
Serial RX +
Speaker +
Speaker -
Mic -
Mic +
Surface Reset
Ground
No Connection
Ground
Record Control Connector
Pinout Table
Control Surface Cable Pinout
Tables (both cable ends are shown)
TS612 Control Surface (DB15F)
Description
Serial TX -
Serial TX +
Serial RX -
Serial RX +
Speaker +
Speaker -
Mic -
Mic +
Surface Reset
Ground
No Connection
Ground
55
Pin
1
2
3
4
5
6
7
8
9
10
11-14
15