  • Page 1: Table Of Contents

    Replacing anti-condensate heater element around frame of hinged Reach-In doors Pressure Relief Port Replacing klixon on Pressure Relief Port Replacing anti-condensate heaters on Pressure Relief Ports Replacing magnetic gasket on Pressure Relief Ports Door Closer Replacing Door Closer REV: 5/2013 IM-268S-11 2013 © Bally Refrigerated Boxes, Inc.
  • Page 2: Im-268S

    A. Remove old worn Safety Walk Strips from Walk-In floor, ramps, or a stepplate. See figure 1. B. Clean and completely dry areas where new strips are to be placed. C. Install new strips on to the Walk-In floor pressing them firmly in place. Figure 1 IM-268S-11 2013 © Bally Refrigerated Boxes, Inc.
  • Page 3: Gaskets

    See Figure. 3. Part Numbers: #016614 – 30” Door #016611 – 34” Door #054028 – 36” Door #016612 – 42” & 48” Doors #016613 – 60” Door REV: 5/2013 IM-268S-11 2013 © Bally Refrigerated Boxes, Inc.
  • Page 4: Hinged Walk-In Doors

    This will firmly secure the latch handle in place for use. H. Open and close the door several times to assure proper operation of the latch. Figure 4 IM-268S-11 2013 © Bally Refrigerated Boxes, Inc.
  • Page 5: Replacing D-1250 Spring Loaded Hinges On Walk-In Door Panels

    See Figure 7. Where tamper-proof screws are used, loosen them tapping screw head counterclockwise with a center-punch and hammer as shown in Figure 5. C. Retighten machine screws and check door cap for proper seal. Figure 7 REV: 5/2013 IM-268S-11 2013 © Bally Refrigerated Boxes, Inc.
  • Page 6: Anti-Condensate Heaters

    I. Reconnect the new heater element to the heater wire leads. Recaulk the opening in the door frame where the heater wire passes through into the junction box. This is very important. J. Re-energize the outside power source to the door frame light junction box. Check for proper operation. Figure 8 IM-268S-11 2013 © Bally Refrigerated Boxes, Inc.
  • Page 7: Reach-In Doors

    Turn cam in direction of the arrow in increase clearance; opposite direction to decrease. e. Hold cam in position and tighten bottom nut securely. 3. Replace the door on its hinge bases. Check to make sure door operates properly. Figure10 Figure 9 REV: 5/2013 IM-268S-11 2013 © Bally Refrigerated Boxes, Inc.
  • Page 8: Replacing Hinges On Reach-In Door Panels

    (Be careful not to break or pinch the heater element.) Replace the door on the hinge bases. H. Re-energize the power source to the door frame junction box. Check the door for proper operation and seal. IM-268S-11 2013 © Bally Refrigerated Boxes, Inc.
  • Page 9: Pressure Relief Port

    See Figure 15. D. Caulk around the perimeter of the opening, and replace the port. Rewire and replace the junction box cover. Reconnect electrical power. See Figure 16. Figure 15 Figure 16 REV: 5/2013 IM-268S-11 2013 © Bally Refrigerated Boxes, Inc.
  • Page 10: Replacing Door Closer

    Figure 17 Part Number: #031349 – Dictator Hydraulic Door Closer V1600B IM-268S-11 2013 © Bally Refrigerated Boxes, Inc.