Replacing Fresh Food Evaporator Using The Lokring Method - GE PSH23PGR Series Technical Service Manual

Arctica side-by-side dual evaporator refrigerators with electronic touch controls
Hide thumbs Also See for PSH23PGR Series:
Table of Contents

Advertisement

13. Connect the capillary tube to the inlet tube
of the evaporator. Connect the
OD copper tube to the outlet tube of the
evaporator (remove any excess length as
required to obtain the correct fi t).
14. Apply a liberal amount of thermal paste
around both epoxy joints to prevent heat from
damaging joint integrity.
15. Install a metal brazing shield between the
joints and the plastic liner.
16. Protect the freezer fl oor from molten solder
during brazing.
17. Angle torch so that the fl ame is directed away
from the plastic liner. Braze both joints. Clean
and inspect joints. Remove the brazing shield.
18. Clean thermal paste off the joints. Dress the
joints to the right of the freezer evaporator
so the freezer evaporator cover can be
reinstalled without interference.
19. Reinsert the thermistor into the aluminum
block on the rear of the new fresh food
evaporator.
20. Attach the evaporator to the fresh food liner
using the original screws. Ensure that the
drain pan is properly positioned. Install a new
Styrofoam block into the hole of the mullion.
Attach foam tubes to evaporator inlet/outlet
tubes using wire tie provided.
21. Remove the old drier by cutting the condenser
loop as close as possible to the drier. Install
the new drier assembly, making sure that
there is suffi cient space between the tubing.
Install the access tube on the compressor.
22. Evacuate and charge the system. Use original
factory charge quantity of R-134a. (See
Evacuation and Charging Procedure
23. Replace all component parts in both the
freezer and the fresh food compartments.
24. Reinstall the rear access cover.
Replacing Fresh Food Evaporator Using
5
/
-in.
16
the
Parts Needed:
Drier Assembly (part # WR86X93)
Process Tube (part # WJ56X61
LOKRING
Note: If it is determined that the epoxy joints
(transition joint between the aluminum and copper
jumper) on the freezer evaporator assembly are
defective, then
to repair the joints. Refer to Pub. No. 31-9067 for
more
1. Follow steps 1 through 9 under
Fresh Food Evaporator Using the Brazing
Method.
2. Using the tube cutter, cut both copper tubes
as close to the epoxy joint as possible. Leave
as much
LOKRING
3. Remove the fresh food evaporator.
4. Modify replacement evaporator to use
LOKRING
a. Using the tubing cutter, cut the jumper
b. Cut the jumper tube on the inlet end of the
.)
– 39 –
Method
LOKRING
Connectors (part # WR97X10021)
connectors can be used
LOKRING
information.
LOKRING
5
/
-in. tubing as possible for a good
16
connection.
connectors.
tube at the outlet end of the evaporator
2 inches from the epoxy joint.
evaporator (capillary joint) 1
the epoxy joint. Make two joints using the
connectors for
LOKRING
copper joints.
Inlet Tube
Outlet Tube
2"
1-1/2"
Epoxy
Joints
Replacing
1
/
inches from
2
5
/
-in. copper to
16

Hide quick links: