Lennox Hearth Products Ladera-BK Installation And Operation Instructions Manual

Lennox Hearth Products Ladera-BK Installation And Operation Instructions Manual

Epa wood-burning fireplace signature collection

Advertisement

SAVE THESE INSTRUCTIONS
FOR FUTURE REFERENCE
WARNINGS
Hot! Do not touch! The glass and
surfaces of this appliance will be hot
during operation and will retain heat
for a while after shutting off the appli-
ance. Severe burns may result.
Carefully supervise children in the
same room as appliance.
Listed to standards:
ULC-S610 and UL-127
Report # 3151759
INSTALLATION AND

OPERATION INSTRUCTIONS

EPA Wood-Burning Fireplace
P/N 506023-03 REV. B 05/2009
MODELS
Ladera-BK
Ladera-BN
This installation manual will enable you to obtain a safe, efficient and
dependable installation of your fireplace system. Please read and
understand these instructions before beginning your installation.
Do not alter or modify the fireplace or its components under any circum-
stances. Any modification or alteration of the fireplace system, including
but not limited to the fireplace, chimney components and accessories,
may void the warranty, listings and approvals of this system and could
result in an unsafe and potentially dangerous installation.
Lennox Hearth Products wood-burning fireplaces are designed for use
as a supplemental heater. They are not intended for continuous use
as a primary heat source.
• The fireplace cannot be operated without a door
or firescreen. Consult your dealer to select the
correct replacement door or firescreen.
• The fireplace is equipped with a blower, electri-
cal connection must be made prior to fireplace
installation
• Important! To assure proper alignment of glass
doors: Install this fireplace in a square and
plumb condition, using shims as necessary at
sides and/or bottom.
• Install the fireplace only as described in these
instructions.
PILADERA REV. 2 05/2009
Ladera™
WARNINGS
TM

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Ladera-BK and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Lennox Hearth Products Ladera-BK

  • Page 1: Operation Instructions

    Lennox Hearth Products wood-burning fireplaces are designed for use as a supplemental heater. They are not intended for continuous use as a primary heat source.
  • Page 2: Safety Rules

    IMPORTANT! GENERAL SAFETY WARNING WARNING PRECAUTIONS. READ AND UNDERSTAND THESE SAFETY Be careful adding wood fuel to the Use care when selecting window RULES BEFORE YOUR FIRST FIRE. fire or handling fireplace tools such treatments for windows located near the fireplace. Avoid using as shovels, tongs or pokers.
  • Page 3: Table Of Contents

    AC Chimney - Outside Air Kit (required if using AC Chimney) Thank you for selecting a Lennox Hearth Products fireplace as the answer to your home - Chimney Adaptor 7 inch (6AW7) supplemental heating needs. (If you choose to use 7 inch ASHT or...
  • Page 4: Starting And Maintaining A Fire

    First Fires precise control of the fire. The combustion air For instance, a long chimney will necessitate control is located below the door on the left side. closing the damper more. To obtain the proper Before using the fireplace make sure to remove The main source of air (primary air) entering combustion, close the damper completely, then the firebox can be diminished by moving the...
  • Page 5: Important Cautions

    MAINTAINING YOUR FIREPLACE A. Negative pressure in the house 5. Check outside to ensure that sparks and hot As the fire burns, air goes up the chimney. embers coming out of the chimney are not This air must be replaced through leakage igniting the roof.
  • Page 6: Disposing Of Ashes

    To replace the refractory bricks, follow WARNINGS these steps (see Figure 3): 1. Remove the bottom refractory • Use only a Lennox Hearth Products glass doors, specifically designed 2. Remove the front refractories for the Ladera™ fireplace. 3. Remove the left side refractory • The fireplace cannot be operated without door or firescreen.
  • Page 7: Glass Care - Replacement

    This replacement part is available from your Page 23). DO NOT OPERATE THE UNIT WITH if additional support is needed. Lennox Hearth Products dealer in the following CRACKED OR BROKEN GLASS. dimensions: The Ladera fireplace may be installed directly...
  • Page 8: Optional Cast Facade Installation

    Optional Cast Facade installation WARNING: THE HEARTH EXTEN- Install the Facade per instructions provided in Fireplace SION IS TO BE INSTALLED ONLY Facade Kit (ordered separately - see Page 21). AS ILLUSTRATED. Framing, Facing And Mantel The crack between the fireplace and the hearth extension must be Safety Metal Strip The construction of the framing, facing, and...
  • Page 9: Framing, Facing And Mantel

    Back Wall of Chase/Enclosure OUTSIDE CHASE Including Finishing Materials, if any Corner Installation FRAMING DIMENSIONS 19-19/32” 35-7/8 911 mm 37-5/8” 956 mm * Zero Clearance 29-1/8” 740 mm From Back Spacer to Wall 12-1/2” 318 mm 70” 1778 mm 35” 889 mm Rough Framing Face (Unfinished Shown) 20-1/2”...
  • Page 10 Insulate Joists Same As Ceiling Insulated Chase Construction Storm Collar Roof Support Flashing Draft Stops Attic Radiation Shield NOTE: It is recommend- Floor ed that the chase walls Ceiling Firestop and floor be insulated in Wall the same manner, using the same insulation, as CTDT Termination the rest of the building, below the attic. • Must have the same firestopping resistance as adjacent wall. Note: Non- Combustible •...
  • Page 11: Fireplace Blower

    Once the repair is done, it is mandatory to apply a new high temperature black cement Only non-combustible mate- Frame (Mill-Pack, available from your retailer) rial should be superposed or projecting over the front of sealing the access plate and all screw holes. Grill the fireplace.
  • Page 12: Central Forced Air Kit

    Ladera™ fireplace hot air exhaust. thermostat will turn on the blower when the openings. Fix the adaptors on the fireplace 7. Use only Lennox Hearth Products grills and room where the fireplace is located becomes openings by turning clockwise (Figures 14 components as described in this manual.
  • Page 13: Outside Air Kit

    Adaptor Insulated Flex Pipe Figure 17 Insulation Blower Flex 5” Diameter Tightening Collar Aluminum Tape Figure 18 (fireplace and AC chimney) OUTSIDE AIR KIT The outside air kit is optional on the Ladera™ fireplace, but mandatory on the AC chimney. It can be burned drawing air only from the house. When the fireplace is in operation with the door closed, it will pull only a slight amount of air from the house.
  • Page 14: Chimney System

    2. The Lennox Hearth Products fireplace model Ladera may be installed D) The air intake should be installed where it is not likely to be blocked by only with Security Chimneys International 6”...
  • Page 15: Chimney Installation Instructions

    CHIMNEY INSTALLATION Attic Radiation Shield INSTRUCTIONS Attic Radiation ASHT / S2100 Air Cooled Pipe Shield HT6103+ / HT6000+ 1. Cut and frame the holes in the ceiling, floor Solid Packed Pipe and roof where the chimney will pass (see Figure 23). Use a plumb-bob to line up the center of the holes.
  • Page 16: Offset Chimney Installation

    After reaching the location requiring the elbow, proceed as follows: Air Cooled Chimney Chimney ASHT+ / HT6103+ / S-2100+ / HT6000+ Collar Chimneys Spacer (built 1. Install the first elbow; turn it in the required into flashing) direction. Fasten it to the chimney with the three (3) 1/2”...
  • Page 17 Offset Dimensions Total Height Horizontal Offset Chimney Elbow Offset & One Length Between Elbows Two Lengths Between Elbows 6” Height 8” 12” 18” 24” 36” 48” 8” & 48” 12” & 48” 18” & 48” 24” & 48” 36” & 48” 48”...
  • Page 18: Angled Wall Radiation Shield

    ANGLED WALL RADIATION SHIELD (RSM+ and RSMI30) OFFSET CHIMNEY INSTALLATION When traversing a combustible wall with the chimney at a 30º or 45º Chimney AC angle, an angled firestop or wall radiation shield must be installed. Only one is required. RSMI45) Note: 45º angle for Canada only ( In cold climate locations (climates where temperatures will fall below 32°...
  • Page 19: Chimney Support Installation

    CHIMNEY SUPPORT INSTALLATION Universal Roof Support This support has three possible uses: 18” (460 mm) 18” (460 mm) 1. For ASHT+ / HT6103+ and S-2100+ / HT6000+, it must be used on a roof to support the chimney. 2. It may be used on a floor, ceiling or roof above an offset to support the chimney above the offset.
  • Page 20: Masonry Application Instructions

    INSTALLATION INSTRUCTIONS FOR MASONRY APPLICATION Follow these steps: 1. Position the fireplace in its location. Temporarily install the ASHT+ WARNING: Before starting the installation, the masonry chimney elbow on the top of the fireplace and, using a level, mark with an oval must be inspected by a qualified chimney sweep.
  • Page 21: Installation Accessories

    OPTIONAL INSTALLATION ACCESSORIES Cast Surround Kit Description Cat./ Part No. Installation Accessories Cast Surround Kit, CSK H7303 Description Cat./ Part No. Cast Surround Decorative Keystone, CSK-DK H7757 Outside Air Kit Outside Air Coupler To Connect Outside Air (UZI) To Fire- UZIAD CHIMNEY - PARTS AND COMPONENTS LISTS place, UZIAD...
  • Page 22 CHIMNEY - PARTS AND COMPONENTS LISTS TUBINOX LL Chimney Lining System (AC) Air-Cooled Chimney System* Rigid Stainless Steel Liner For Relining A Masonry Chimney, 6” Diameter 6” I.D. and 11” O.D. Air Cooled, Stainl. Steel inner and zinc coated steel exterior Listed to ULC-S635M, UL-1777 and ULC-S640M at 2100º...
  • Page 23: Replacement Parts

    70K99 (Except the wood framing. See Page 9, Figure 8) Chimney: 2” (50mm) Contact an Authorized Lennox Hearth Products dealer to obtain any of these parts. Never use substitute materials not approved by Lennox Mantel: 39’’ (990mm) measured from the base of the fireplace.
  • Page 24: Product Reference Information

    Your Dealer's Name _________________________________________________ Your Dealer's Phone Number __________________________________________ Lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information.

This manual is also suitable for:

Ladera-bn

Table of Contents