Note:
Note: When sample rate conversion is active, the input signal is truncated to 20
Note:
Note:
Note:
bits, causing a slight degradation in the signal quality of a 24-bit input. Therefore
sample rate conversion should be enabled only when intentionally converting a
signal to a different sample rate (e.g., from 44.1k to 48k), or when no other means
exist to establish clock synchronization with the device(s). See the Technical Ref-
erence Guide for details.
18
HDR 24/96
1. Select Setup from the Windows menu (or use
keyboard shortcut CTRL+1).
2. Click the Digital I/O icon. For each PDI•8 card,
click the Setup button. In the AES/EBU Setup
dialog, check the Converted boxes corresponding
to the desired input(s) to enable sample rate
conversion; leave the boxes unchecked for no
sample rate conversion (default).
3. Then select Pro (default) or Consumer from the
pulldown menus associated with the desired
output(s). Click the arrow in the top right corner of
the dialog or hit ESC to exit.
AIO-8
DIO-8
ADAT
ADAT
I/O Card 17-
24
PDI-8
Setup
Setup AES Card - Slot 3
Sample Rate Conversion:
1- 2
Converted
3- 4
Converted
5- 6
Converted
7- 8
Converted
Optimal settings are - NOT converted and Pro.
Stadus Bits: