Amplifier Mode - RAM 6000V Operation Manual

Professional power amplifiers
Table of Contents

Advertisement

Installation and
Operation
Amplifier Setup: when you are in the Main Menu and access to the Amplifier Setup section, you can change different amplifier
parameters, change the current preset and protect the access using a password. The Menu development for this section is the
next:
Preset Manager
Load
Save
Inputs Link
IN-A
IN-B
Amplifier Gain [dB]
32dB
32dB

Amplifier Mode

BRDG
BRDG
Attenuators Link
Disabled
ICL Clip Limiter
Enabled
Password Control
Enabled
Del
Rest
IN-C
IN-D
32dB
32dB
DUAL
DUAL
11
Preset Manager: you can change quickly the amplifier preset
configuration. To access to any option you have to enter in
Edit mode (pressing CH-A knob) and turn the corresponding
encoder: CH-A for Load, CH-B for Save, CH-C for Delete and
CH-D for Restore default. Select a preset number from 0 to 9.
Inputs Link: you can Link the input signal to the next chan-
nel. Enter in Edit mode and turn the CH-B, CH-C or CH-D
knob to link the input to the previous channel.
WARNING! You have to remove the
input connector of the linked channel!
Amplifier Gain: you can change independently the amplifier
gain for each channel from 26dB to 38dB (0.5dB steps). Enter
in Edit mode and use the corresponding channel knob to
modify it.
Amplifier Mode: it configures the amplifier in Dual or Bridge
mode. In Edit mode use the CH-A or CH-C channel knob to
change the option.
Attenuators Link: you can link all attenuators to modify the
output level for all channels simultaneously. When you
change this option to Enabled, you modify the attenuation for
all channels using any channel knob.
ICL Clip Limiter: you can turn on or turn off the ICL Clip
Limiter for all channels. We recommend to you to work with
this option enabled to avoid any damage to the speakers.
Password Control: you can define a password to prevent
any modification of the amplifier configuration. When you turn
on this option, you have to introduce a password using the
four knob encoders, and confirm it. After that, you need to
introduce this password each time you want to modify the
amplifier configuration. There is a generic password which
you can use to disable the Password Control, it is: 5 5 5 5

Advertisement

Table of Contents
loading

This manual is also suitable for:

9000v12000v9004v90441200412044 ... Show all

Table of Contents