LG LFX25973 Series Service Manual page 40

Lg lfx25973 refrigerator service manual
Hide thumbs Also See for LFX25973 Series:
Table of Contents

Advertisement

9-8 Over cooling in Refrigerator room
No
1
Check the R Sensor resistance.
<CON7>
※ The R Sensor is determined by
the temperature.
For example, 30㏀ indicates 32°F.
2
Reset the unit and
Input Test 1 Mode.
(Push the button 1 time)
3
Open Refrigerator room door and Check
the air flow.
4
Input Test 2 Mode and
Check the air flow.
(push the button 1 more time)
5
Check the damper resistance.
(3)
(2)
Checking flow
(1)
(4)
Result & SVC Action
Temperature
23°F / -5°C
32°F / 0°C
41°F / 5°C
50°F / 10°C
59°F / 15°C
Status
Windy
No windy
Status
Windy
No windy
Test
Point
270 ~ 330 Ω
(1) To (2)
270 ~ 330 Ω
(3) To (4)
- 40 -
Result
38 ㏀
30 ㏀
24 ㏀
19.5 ㏀
16 ㏀
SVC Action
Go to the 4
Check the R Fan Check
the damper (Go to the 5)
SVC Action
Go to the 5
It's normal
Result
SVC Action
It's normal
Change damper
Other
It's normal
Change damper
Other

Hide quick links: