Wrong connection can cause over heating or fire. • bed and breakfast type environments. • This hot water system should be installed in accordance with AS/NZS 3000 and your electricity suppliers rules. 2 contents Kelvinator gas continuous flow hot water system...
Do not allow the power cord to rest close to hot surfaces. It may cause fire and electric shock. Do not disassemble or modify water heater. It may cause failure and electric shock. Kelvinator gas continuous flow hot water system important 3...
1. Cannot be seen 2. Vapours are heavier than air 3. Go a long way on the floor 4. Can be carried from other rooms to the main burner by air currents 4 important safety instructions Kelvinator gas continuous flow hot water system...
15 BSP Ignition Electronic Electronic Electrical Supply Voltage 240 AC 240 AC Operating current 0.8A 0.8A *The water heater will operate at reduced performance when inlet water supply pressures are below 340kPa. Kelvinator gas continuous flow hot water system specifications 5...
Note: If there is a risk of freezing conditions, do not switch off power to the water heater unless it is drained of water first. Please see the section on freeze prevention on page 9 of this manual for more information. 6 how it works Kelvinator gas continuous flow hot water system...
Do not turn on power to the water heater and keep potential ignition sources away. Call a service technician to inspect and repair the leak. Kelvinator gas continuous flow hot water system initial operation 7...
ON/OFF button of 37°C to 50°C. Note: If you have an "A" series main remote controller installed it will have max temperature setting option of 55C. 8 normal operation Kelvinator gas continuous flow hot water system...
6. Wait a few minutes to ensure all water has completely drained from water heater. 7. Securely screw the drain plugs back into place. Hand-tighten only. power supply drain plug manual gas valve manual water cold valve Kelvinator gas continuous flow hot water system freeze prevention 9...
With a tiny brush, clean the water filter of any debris which may have accumulated and reinsert the filter back into the cold water inlet. 8. Securely screw the drain plugs back into place. Hand- tighten only. 10 maintenance and service Kelvinator gas continuous flow hot water system...
Check the error code on the PCB (see page 19 for details). Remote controller can not change Is priority lamp lit? If it is not, press the priority button after closing all hot the set temperature. water taps. Kelvinator gas continuous flow hot water system troubleshooting 11...
Page 12
Notes 12 notes Kelvinator gas continuous flow hot water system...
Page 13
Notes Kelvinator gas continuous flow hot water system notes 13...
Page 14
Notes 14 notes Kelvinator gas continuous flow hot water system...
Appliance was installed according to the Electrolux installation between you and Electrolux are governed by the law applicable where guidelines which can be inspected on the Kelvinator website; the Appliance was purchased. Where the Appliance was purchased in • Hot water tank cylinders - parts 5 years , labour 3 years New Zealand for business purposes the Consumer Guarantee Act does •...