  • Page 1 OPERATING INSTRUCTIONS SIR 800 Compact Transmitter...
  • Page 2 For further information about our products, please go to our website: http://www.beyerdynamic.de © 2007 beyerdynamic, Heilbronn All rights reserved, especially (also partly) the translation, reprint, reproduction through copying or other similar methods. beyerdynamic reserves the right to make changes without notice. Nov-07...
  • Page 3 SIR Infrared System SIR 800 CAUTION DANGER OF ELECTRIC SHOCK DO NOT OPEN DEVICES Do not open housing with mains cable connected. Maintenance operations may only be executed by qualified personnel. Our equipment and installations have been built and tested according to the latest state of the art. Under normal conditions, they do not require any special maintenance.
  • Page 4: Sir Infrared System Sir

    SIR Infrared System SIR 800...
  • Page 5: Table Of Contents

    2.8 Important information ..........................6 3. Short description......................7 3.1 System function ............................. 7 3.2 Use ................................... 7 3.3 SIR 800 Compact transmitter ........................8 4. Installation and starting up ..................10 4.1 Connecting the LINE-IN socket ....................... 10 4.2 Connecting RF-LINK socket ........................10 4.3 Connecting radiator sockets........................
  • Page 6: About This Manual

    SIR Infrared System SIR 800 1. About this manual Symbols The following symbols and fonts are used in this manual: Indicates an important note, which has to be followed to guarantee that the functions of the unit, the security of any data or your health are not put at risk...
  • Page 7: Important Remarks

    Check that the operating voltage of the unit is identical with the voltage of your local mains power. If a voltage conversion is required, consult your beyerdynamic dealer or qualified personnel. Should any liquid or solid object fall into the cabinet, unplug the unit and have it checked by qualified personnel before it will be used again.
  • Page 8: Repacking

    We recommend using this system for long-term protection and care. 2.7 General Please keep this manual together with the compact SIR 800 transmitter. If you hand on the units to third parties, please include this manual. Please read the manual carefully, taking special care when you see this symbol as it indicates...
  • Page 9: Short Description

    3.1 System function The SIR system consists of several components: The central component is the compact SIR 800 transmitter. The inputs are signals from several audio channels (for instance, several different language channels with simultaneous interpretation). It converts them into the appropriate FM signals for wireless transmission.
  • Page 10: Sir 800 Compact Transmitter

    Seven languages and the original (floor channel) can be transmitted. On the front right-hand side of the compact SIR 800 transmitter there is a green POWER ON showing the ON/OFF status. Next to this there are three infrared test diodes emitting the IR-signal. With the IR receiver you can listen to the outgoing channels even without IR-Radiator.
  • Page 11 Mains power connector. • Separate earth connection via special bolt • Unused audio channels of the SIR 800 should be turned off to increase the infrared power of the SIR 801 radiator for the actual number of channels in use.
  • Page 12: Installation And Starting Up

    When installing several SIR 800 above each other, leave 1 U at least free between them. If the SIR 801 radiator is mounted to the ceiling, please use a safety rope to protect it from falling down.
  • Page 13: Starting Up

    SIR 800 5. Starting Up The power supply is turned on via the power switch on the front side of the compact SIR 800 transmitter. When you use the compact transmitter the first time it is necessary to adjust the provided channels.
  • Page 14: Operation

    SIR Infrared System SIR 800 6. OPERATION Once the SIR system has been properly started up and checked, there is usually no need for any further intervention from the operator. Most of the work involved with audio distribution should have been completed during the pre-selection of channels and system start-up.
  • Page 15: Overview

    SIR Infrared System SIR 800 6.3 Overview Power switch Illustration 1 AF indicator ON LED DIP-switch setting Channel 3 IR diodes LED green channel range selection LINE-IN Mains Power Link connector Radiator connectors Illustration 2...
  • Page 16: Technical Data Sir 800

    1: Connection for up to 10 SIR 801 Radiators 2: Connection of up to 10 further SIR 801 Radiators RF-LINK (1 x BNC-socket) • for cascading (RF) with further SIR 800 Features Green lighted mains switch for power ON indication •...
  • Page 17: Optional Accessories

    SIR Infrared System SIR 800 6.5 Optional accessories (not included in delivery) SIR 801 Radiator • SIR 320 Receiver • BNC cable (50 Ohm) different length available • CA 5103 BNC-T-adapter • CA 5102 BNC-BNC-adapter • CA 5101 50-ohm terminating resistor...
  • Page 18: Troubleshooting

    SIR Infrared System SIR 800 Troubleshooting Error description Error cause Error solution Switching system The main cable connector is not Check if there is no connection to produces POWER properly connected the mains power. condition (green LAMP does not corresponding socket of the unit.
  • Page 19: Warranty

    SIR 800 Warranty beyerdynamic GmbH & Co. KG provides you with two years’ guarantee on brand-new devices from the date of purchase. Please save your sales receipt and this guarantee supplement. Without this proof repairs can fundamentally only be carried out for a charge. The guaranteeing includes materials and working time for the elimination of demonstrable defects in material or workmanship.
  • Page 20 SIR Infrared System SIR 800 NOTES...
  • Page 21 SIR Infrared System SIR 800 NOTES...
  • Page 22 SIR Infrared System SIR 800 NOTES...
  • Page 23 SIR Infrared System SIR 800 NOTES...
  • Page 24 GmbH & Co. KG Theresienstr. 8 74072 Heilbronn – Germany Tel. +49(0)7131-617-0 Fax +49(0)7131-617-224 info@beyerdynamic.de www.beyerdynamic.de beyerdynamic U.K. Ltd. 17 Albert Drive Burgess Hill RH15 9TN Tel. +44(0)1444-258258 Fax +44(0)1444-258444 sales@beyerdynamic.co.uk www.beyerdynamic.co.uk beyerdynamic Inc. USA 56 Central Ave. Farmingdale, NY 11735 Tel.