Download Print this page

Madell QK982 Operating Manual page 2

Syrup dispenser

Advertisement

(2).Diagram of front and rear panels
5
4
VA C U U M
50
3
4
+
-
2
5
1
6
0
7
6
FU SE 0. 25
S ETU P
11
10
(3)Adjustment of dispensing time and interval
time
Mode switch on the rear panel of the unit
can be adjusted according to the
following table to suit different needs.
(a). Adjustment of dispensing time and interval time.
The dispensing time control button is located on the front panel of the unit.
The dispensing time can be set directly. Press the "+" button, and the
corresponding digit will increase by one. Similarly, press the "- "button,
the corresponding digit will decrease by one. There are four digits in the
display, with a range from 0.01 second to 99.99 seconds, and the resolution
is 0.01 second.
(b). Interval Time Setup
The interval time control button is located on the front panel of the unit.
The interval time can be set directly. Press the "+" button will increase
the interval by one. Similarly, press the "- "button will decrease the
interval by one. There are two digits in the display, with a range from 0.1
second to 9.9 seconds, and the resolution is 0.1 second.
3
2
1
AI R P R E SS U R E
I N TE R V AL
O N
D I S PE N SI N G TI M E
O FF
7
100 PSI MAX
FO O TSW I R TC H
0.7 MPa MAX
AIR IN
9
8
ON
1
2
3
4
Item
Mode Switch Status
No.
S1
S2
S3
S4
1
OFF
OFF
OFF
OFF
2
ON
OFF
OFF
OFF
3
OFF
ON
OFF
OFF
4
ON
ON
OFF
OFF
5
OFF
OFF
ON
OFF
6
ON
OFF
ON
OFF
7
OFF
ON
ON
OFF
8
ON
ON
ON
OFF
9
OFF
OFF
OFF
ON
10
ON
OFF
OFF
ON
11
OFF
ON
OFF
ON
12
ON
ON
OFF
ON
13
OFF
OFF
ON
ON
14
ON
OFF
ON
ON
15
OFF
ON
ON
ON
16
ON
ON
ON
ON
Note: Dispensing at controlled time means dispensing according to set dispensing time
and interval time.
Function
With pedal switch pressed, dispense
continuously, otherwise it will
stop dispensing.
Be triggered once, dispense at controlled time
once.
Be triggered once, dispense at controlled time
twice.
Be triggered once, dispense at controlled time
three times.
Be triggered once, dispense at controlled time
four times.
Be triggered once, dispense at controlled time
five times.
Be triggered once, dispense at controlled time six
times.
Be triggered once, dispense at controlled time
seven times.
Be triggered once, dispense at controlled time
eight times.
Be triggered once, dispense at controlled time
nine times.
Be triggered once, dispense at controlled time ten
times.
Be triggered once, dispense at controlled time
eleven times.
Be triggered once, dispense at controlled time
twelve times.
Be triggered once, dispense at controlled time
continually,
the
next
trigger
dispensing.
With pedal switch pressed, dispense at controlled
time continually, or it will stop dispensing.
Dispense at controlled time continually and
automatically.
will
stop

Advertisement

loading