Water Connections - American Water Heater DIRECT VENT GAS WATER HEATER Installation And Operating Instruction Manual

American water heater co direct vent gas water heater installation and operating instruction manual
Table of Contents

Advertisement

WATER CONNECTIONS

Note: BEFORE PROCEEDING WITH THE INSTALLATION, CLOSE THE
MAIN WATER SUPPLY VALVE.
After shutting off the main water supply, open a faucet to relieve the water
line pressure to prevent any water from leaking out of the pipes while making
the water connections to the water heater. After the pressure has been
relieved, close the faucet. The COLD water inlet and HOT water outlet are
identified on the top of the water heater. The fittings at the cold water inlet
and hot water outlet are dielectric waterway fittings with 3/4" NPT male
thread. Make the proper plumbing connections between the water heater
and the plumbing system to the house. Install a shut-off valve in the cold
water supply line.
If sweat fittings are to be used, DO NOT apply heat to the nipples on top
of the water heater. Sweat the tubing to the adapter before fitting the
adapter to the water connections. It is imperative that heat is not applied
to the nipples containing a plastic liner.
CAUTION