Summary of Contents for LightSpeed Technologies FP 100
Page 1
FP 100 LightSPEED Infrared Wireless Microphone System U s e r M a n u a l...
Page 2
With its small footprint, the FP 100 can mount in any discrete location— whether it is an audio visual cabinet or below-ceiling tray. The FP 100 is a compact, two-channel receiver that allows the use of up to two wireless microphones simultaneously in the classroom. A standard IR sensor provides high quality reception in rooms up to 1600 square feet.
This 5. Water and Moisture— LightSPEED product should not be used near water. This LightSPEED product 6. Heat— should be situated away from heat sources such as radiators, etc. ii | FP 100 User Manual...
F P 1 0 0 U s e r M a n u a l F P 1 0 0 U s e r M a n u a l TABLE OF CONTENTS FP 100 INFRARED WIRELESS MICROPHONE SYSTEM Safety Instructions ....................System Components ....................
F P 1 0 0 U s e r M a n u a l SYSTEM COMPONENTS FP 100 Infrared Wireless Microphone System Sensor Cable SR-70F Infrared Sensor Power Supply Charger LT-71 LightMic™ Transmitter Audio Patch Cable Optional HM-70 Handheld Microphone Helpful Keep ALL packaging materials.
This light confirms the FP 100 is 8. B/MIX SWITCH: This switch receiving a steady infrared signal. determines the audio source that is output through the CH.B/ These lights 4.
1. SENSOR SHORT: cable connects to the sensor input when there is a short in one of jacks. Connect additional sensors to the sensor cables. the FP 100 to cover large or odd-shaped rooms. 3 | FP 100 User Manual...
Channel A or B. If you are Plug Charger Input (CHARGER): using a single microphone/ the charging cable from the FP 100 transmitter for your system, we into this jack for daily charging. recommend using Channel A. The LED on the front will glow red to indicate charging.
ON. pre-set at the factory and no Plug Charger Input (CHARGER): adjustment should be necessary. the charger into this jack for daily charging. The LED on the front will glow red to indicate charging. 5 | FP 100 User Manual...
F P 1 0 0 U s e r M a n u a l SYSTEM INSTALLATION Unpacking Your System Location of the Receiver Place the FP 100 on a flat surface like a Ensure that you have received all of cabinet, shelf, or tray. the components of your system.
Page 11
F P 1 0 0 U s e r M a n u a l SYSTEM INSTALLATION (cont’d) the stripped wires into the marked openings, left and right, in 3. Insert the Euro-block. Euro-block the inserted wires by tightening the retaining screws. 4. Secure 7 | FP 100 User Manual...
¼˝ connector into the 5. Connect audio or microphone input on the existing amplifier. FP 100 Mixed Audio Connection (Not Recommended) This method allows for individual control of each microphone channel from the amplifier being used. a second balanced audio cable.
IR SENSOR INSTALLATION Sensor Placement in the Classroom Sensor location is very important for optimum performance of the FP 100 IR Wireless Microphone System. • BEST: On the ceiling at or near the middle of the < GOOD < BEST classroom.
1. Ensure 2. Ensure controls are turned fully securely connected into the FP 100 and the counterclockwise. mixer/amplifier. Make sure the CH.B/MIX switch is in the appropriate setting based on your output method (see pg. 11 for more info).
B VOLUME control. the normal level is set on the FP 100, the user will now use the 6. Once mixer/amplifier volume control to adjust the microphone up or down during >>...
5. Slide to turn off the HM-70. (Make sure the power indicator light is off.) The Channel A/B switch is located inside the battery compartment. The switch is set to Channel B at the factory. FP 100 User Manual | 12...
(8–10 hrs.) to obtain a full charge. Helpful Hint Do not attempt to charge alkaline batteries. They can overheat and expand, creating a significant hazard and damaging the LightMic. (This is not covered by the warranty.) 13 | FP 100 User Manual...
HM-70. The HM-70’s rechargeable batteries are factory installed. Helpful All LightSPEED microphone transmitters can remain charging for up to 10 days. Hint Overcharging will not create a hazard, but will shorten battery life. FP 100 User Manual | 14...
(refer to sensor placement in signal is being received at • Confirm manual). A single sensor will cover a the FP 100. The IR signal light will be 1600 sq. ft. enclosed classroom. lit (red) indicating a signal is being received.
ON/OFF switch on the side of the LightMic into the Wall Charger Plug the LightMic to recharge at the end of the day. and speak nor- mally. Set the channel switch to A. FP 100 User Manual | 16...
Repair by other than LightSPEED or its authorized service agencies will void this guarantee. Information on authorized service agencies is available from LightSPEED Technologies, Inc. Our Service Department (800.732.8999, 5 a.m. – 5 p.m., PST) will handle all your repair/replacement needs. 17 | FP 100 User Manual...
1.375” x .75” x 4.625” Weight 3.7 oz. IR SENSOR SPECIFICATIONS Working Range Up to 1600 square feet Cable 6 ft./50 ft., Plenum-rated Mounting Ceiling clip/Wall bracket Dimensions 4.25” (Diam.) x 2.0” (H) Weight 4.5 oz. FP 100 User Manual | 18...
SR70F bracket BC-TXLT Wall Charger Optional Accessories Handheld microphone/transmitter w/batteries and HM70 charging cable AC-71CC Cradle charger Noise-canceling headset microphone to be used MC-TK250LTM with LT-71 Contact LightSPEED at 800.732.8999 for loudspeaker SPEAKERS information 19 | FP 100 User Manual...
Record your system serial numbers and purchase information. This is helpful when ordering additional components, accessories, and/or warranty service. Components Serial Number FP 100 Microphones Sensors Speakers Purchase Information Your School/Organization District Purchase Date Invoice FP 100 User Manual | 20...
Page 25
F P 1 0 0 U s e r M a n u a l USER NOTES 21 | FP 100 User Manual...
Page 26
AC-MN100 L igh tSP EED Te c hno l o gi e s, Inc . 1 1 5 0 9 SW H e rman R d Tualat in, O R 9 7 0 6 2 8 0 0 . 7 3 2 . 8 9 9 9 www.