INSTALLATION INSTRUCTIONS

2013 SERVICABLE
READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
CAUTION! SAFETY PRECAUTIONS
SAVI NOTE is a low voltage light and should NEVER be electrically connected to a power source other than a SAVI
M4 controller. Failure to comply will either damage or destroy SAVI NOTE and VOID the Warranty.
STEP 1
The light
must be installed in the wall of the pool (or
water feature) with the top of the lens opening not less than 4
inches (10.16cm) below the normal water level of the pool.
NOTE: Requires the use of a 1-1/2" threaded wall
1.5" Pipe through bond beam for a minimum of 14" then 1" conduit min. beyond
with sweeps / no 90 degree bends. We highly recommend the use of 1.5" pipe
throughout the entire width of the bond beam. NOTE: Use of 1.5" pipe with 14"
min. length will accommodate all SAVI Lighting nicheless products. Minimum
1.5" conduit length is 7".
STEP 2
Pull the 4 conductor electric cord throught the conduit inlet of the wall
fitting, into the conduit and up to the location of the M4 controller. Cut
off the excessive cord after allowing for a service loop. Pull light snug
into the wall fitting. THIS PRODUCT DOES NOT ALLOW FOR THE
USE OF A JUNCTION BOX INSTALLATION. ALL LIGHTS MUST BE
DIRECTLY WIRED TO THE M4 COTNROLLER.
NOTE: Make sure all protective coverings have been removed.
Winterization Clause
Pool Water Level must be drained down 12" below light(s) position in pool wall.
We also highly recommend that the lights be loosed from their wall
allow drainage of water that might have accumulated within conduit. Consult
your local Swimming Pool Professional for proper local area winterization
processes. At NO TIME should there be water removed from the pool without
checking ground water tables.
Using enclosed Lens Key, thread the light into the wall fitting until it is snug. Please
STEP 3
provide Pool Owner with minimum of 1 key upon job completion (see winterization
clause above)
read the into the wall until it is
WARNING
1. To prevent electrocution and/or death make sure power is off at the breaker.
2. Avoid touching/installing the M4 controller box during electrical storms. Death
or serious injury may result due to lightning surges through the system.
3. Be sure to check local electrical codes for grounding electrical boxes via
the approved method (internal conduit ground, external box ground wire to
grounding rod, etc.)
4. Use approved conduit routed by approved methods to conduit fittings on the
box.
5. For DMX based units, do not install data cables in the same conduit as power
cables to prevent communication problems.
A Division of Next Step Products
SAVI NOTE Underwater LED Light
TURN OFF MAIN POWER TO LIGHT BEFORE INSTALLATION
6. Be sure the mounting surface is able to support the load of the controller. Use all
four mounting holes to secure the controller.
7. There are no customer serviceable components inside the M4 controller. Only
qualified electricians should open the box for installation of the power and LED
accessories connections. All connections should enter through an approved
conduit method.
8. LED accessories are low voltage and should never be electrically connected
to any power source other than the appropriate M4 controller connector (J5 to
J8). Wires must be connected properly to avoid permanently damaging the LED
accessory.
9400 SOUTHRIDGE PARK COURT SUITE 200
Tel:
407.855.5630
NOTE: For Vinyl wall Fittings use both rubber gaskets.
For Gunite and Fiberglass remove the Small
gasket and use the Large one only.
1" min. Pipe
Sweeps ONLY
No 90 degree bends
NOTE: Check with Local Building
Allow 18" - 24"
slack for
Service Loop
NOTE: All lights
must be directly
wired to M4 control
to
Fax:
407.210.8679
Product WATTS AMPS MINIMUM CONDUIT LENGTH
SAVI NOTE 14
1.2
Products are available with 30,50,100 & 150ft cords
Small Gasket
Large Gasket
4" MIN. FROM WATER
LEVEL TO TOP OF LENS
1.5" dia. Pipe
1.5" THREADED WALL FITTING
as to what conduit/pipe is acceptable for usage.
SAVI M4 Controller
4" MIN. FROM WATER
LEVEL TO TOP OF LENS
Conduit to M4
ORLANDO, FLORIDA 32819 USA
nextstepproduct.com
7"
Flat Gasket
4" MIN. FROM WATER
LEVEL TO TOP OF LENS
Vertical Installation for
Benches, Swimouts and
Fountains
Tighten