2.3 ASSEMBLY.

Slide the blower into the slotted bracket on the rear
of the stove. The blower will rest at the bottom of the
slot.
The shaker handle bolts onto the shaker block using
the bolts and lock washers provided.
bolt the draft control through the hole in the center of
the ash door as shown below. The knob should spin
freely and open to a distance of about 3/8 in. from the
door surface, while being able to close against the
face of the door.
Next, lay the glass frame face down on a flat surface.
Place the glass panel into the frame, making sure the
gasket is only applied to the ends of the glass. Now
by placing the door onto the frame, you'll see the
holes will line up with the threaded holes in the glass
frame. Using 4 flange-head bolts from the kit, tighten
the glass frame onto the door.
While the door is still on it's face, position the top trim
into place and secure, through the door, with 2 hex-
head bolts provided. (Mark II or Mark III only)
Installation

2.4 GENERAL INFORMATION.

Installation Checklist:
a. Have your stove installed by a trained installer.
Preferably one who is certified by the National Fire-
place Institute or similar certification agency.
b. before starting Installation, check for proper clear-
ance to combustibles where the stove is going to be
located.
C. Never vent a solid fuel burning appliance into a flue
serving another appliance.
d. Have the chimney inspected and thoroughly
cleaned. Inspect that it is a Class "a" chimney either
masonry or factory built. If it is a manufactured chim-
ney, ensure that it is installed as per the manufactur-
ers requirements. be sure that the chimney is tall
enough. Solid fuel chimneys fall under a general rule,
16 ft. minimum height, 2 ft. taller than anything within
10 ft., and 3 ft. above where it passes through the
roof line. The chimney must be capable of providing a
minimum of .06 inches of water column of draft.
e. limit the amount of connector pipe. Position the
stove as close to the flue as possible. (8 ft. or less)
No more than two 90° elbow fittings should be used.
any horizontal connector pipe should have at least 1/4
in. of rise per foot in length. a barometric damper may
be installed to prevent excessive or erratic draft.
MANUAL DAMPERS OR "HEAT SAVERS" MUST
NEVER BE INSTALLED IN THE FLUE PIPE. IM-
PROPER OPERATION COULD RESULT IN DEATH.