INSTR4038 0302
Installation and
Operating Instructions
For CUNO
Food Service CFS6000 and CFS7000 Series Water Filter Systems
®
CFS6000 Series
Automatic Shut-off • Particulate and Chlorine Reduction •
Optional Scale/Corrosion and Cyst Reduction
Your new CFS6000 Series water filter system is designed
to be installed on the cold water line. The CFS6000 Series
features its own automatic shut-off, thereby eliminating
the need for a shut-off valve on the incoming supply line.
Note: It is advisable to install a drain valve after the system
for routine maintenance. A flush kit can be purchased sep-
arately if a drain valve is not desired. See the CUNO
Service Price List for part number and price.
INSTALLATION PRECAUTIONS
• The filter must be installed with the inlet and outlet as labeled. Make sure not to reverse connections.
• Do not install on hot water line. Maximum temperature allowed is 100°F (38°C).
• Do not install on line pressure above 125 psi (862 kPa).
• Do not use wicking or sealer for fitting connections into head of filter. Use Teflon
• Do not use torch or other high temperature sources near filter system.
• Do not install near electric wires or water pipes which will be in the path of drill when selecting the position to
mount the bracket.
• Do not install in direct sunlight.
• Protect from freezing. Drain filter when room temperature drops below 40°F (4.4°C).
• Allow minimum of 2" (5 cm) clear space under filter to facilitate cartridge change.
• Mount filter in such a position as to prevent it from being struck by other items.
• Installation must comply with existing state or local plumbing codes.
• Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection
before or after the system.
• Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.
CFS7000 Series
Sanitary Quick Change (SQC) • Particulate and Chlorine
Reduction • Optional Scale/Corrosion and Cyst Reduction
Your new CFS7000 Series water filter system is designed
to be installed on the cold water line. This filter system
requires a shut-off valve installed on the inlet water line,
preferably near the filter for convenience.
®
Food
®
Tape for connections.