Multiple Guardshield Type 2S; Mounting Brackets - Allen-Bradley GuardShield Type 2 User Manual

Safety light curtain
Table of Contents

Advertisement

Middle of Depth of Protective Field
Safety Distance
Protective Field Marking
Determining machine stopping time and safety distance
Figure 5:
Multiple GuardShield Type 2
When two or more GuardShield Type 2 are mounted in close proximity
to one another, it may be possible for the receiver of one GuardShield
Type 2 pair to receive infrared light from the transmitter of another
GuardShield Type 2 pair. If two or more pair of GuardShield Type 2 are
mounted in the same plane, the transmitter and receiver pairs must be
mounted in accordance with Figure 6 or a barrier is used to guard against
optical interference.
Multiple GuardShield Type 2 alignment options
Figure 6:

Mounting Brackets

The GuardShield Type 2 is mounted using right angle brackets attached
to the endcaps of both transmitter and receiver. It may be necessary to use
additional brackets to mount the GuardShield Type 2 at a proper safety
distance from the machinery hazard.
Point of Operation
Top of tool
Machine stop time
Bottom of tool
To avoid the possibility of
standing between the protective
field and the point of operation,
the distance must be maintained.
Transmitters emit in opposite
direction. Each receiver receives only
the beams of the appropriate
transmitter.
Positioning of the light curtain:
Transmitters emit in opposite
direction.
Original instructions
GuardShield™ Type 2 Safety Light Curtain Installation Instructions
20
(0.79)
42
18.9
(1.65)
14.5
6.5 (0.26)
40 (1.57)
3.0
32
(1.25)
Mounting brackets
Figure 7:
Optional Middle Mounting Bracket (440L-AF6108)
49.2 (1.93)
40.2
62
24
Figure 8:
Note: Middle mounting brackets should be used in vibration
applications for protective heights of 1120 mm and larger.
52 (2.04)
30 (1.18)
20 (0.78)