UL Listed Models When operating at elevated temperature extremes, the surface may exceed +75°C. For user safety, the 5073E-T should be installed in a restricted access location. The openings on the enclosure are for air convection. Protect the equipment from overheating. Do not cover the openings.
Page 3
Cooper Bussmann/ELPRO Technologies. The offer or supply of these products and services does not include or infer any transfer of ownership. Release Notice This is the November 2013 release of the 5073E-T Managed Ethernet Switch User Manual version 1.1, which applies to firmware version 1.11. Follow Instructions Read this entire manual and all other publications pertaining to the work to be performed before installing, operating, or servicing this equipment.
The switch’s fiber port can extend the connection distance, increasing network elasticity and performance. 1.1 Module Identification The identification label is on the bottom of the 5073E-T Switch. This label contains the model number, temperature range, power range, serial number, and all certifications.
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual 1.3 Order Information Item Product Code Description Data Sheet Ethernet Switch 5073E-T 7+3G-Port Gigabit Managed Ethernet Switch with DIDO 10084 1.4 Hardware Features Feature Description Standard IEEE 802.3 10Base-T Ethernet IEEE 802.3u 100Base-TX/ FX IEEE802.3ab 1000Base-T...
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual Feature Description Power Supply External Power Supply: DC 12–48 V, Redundant power DC 12–48 V and connective removable terminal block for master and slave power. Power Consumption 10.2 Watts (Full load) Operating Humidity...
Each port allows importing 128-bits of alphabetic string on SNMP and CLI interface 1.6 Package Contents Compare the contents of the 5073E-T Switch with the following standard content list. If any item is damaged or missing, please contact your local dealer for service.
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual 2 - harDWarE DESCrIpTION hapTEr This chapter describes hardware specifications, ports, cabling information, and wiring installation information for the 5073E-T. 2.1 Front Panel The front panel includes seven 10/100 TX RJ-45 ports, three 10/100/1000T/ Mini-GBIC Combo ports, each with an RJ-45 and a 100/1000 SFP connector, one RS-232 connector (RJ-45 type) for connecting to a console (terminal or PC), and diagnostic LEDs.
2.2 Top View The top panel of the 5073E-T Switch includes two terminal block connectors. One terminal block has two DC power inputs and one fault alarm, and the other has two digital inputs (DI) and two digital outputs (DO).
Page 12
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual Color State Description P7, P9, P10 (RJ-45) Green (Upper LED) A network device is detected Blinking The port is transmitting or receiving packets from the TX device No device is attached Green (Lower LED)
3.2 DIN Rail Mounting The 5073E-T normally ships from the factory with the DIN rail mount kit installed. If the DIN rail is not installed, refer to Figure 5 to screw the DIN rail onto the switch. Then, follow the steps to mount the switch.
3.3 Wall Mount Plate Mounting Follow these steps to mount the switch using a wall mount plate. 1. Loosen the screws to remove the DIN rail from the 5073E-T Switch. 2. Place the wall mount plate on the rear panel of the switch.
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual 3.4 Wiring the Power Inputs Use the following steps below to insert the power wire. 1. Insert the DC power wires into the contacts for power 1 and power 2, as shown below.
You can connect two devices up to 2 km apart. Gigabit Copper/SFP (Mini-GBIC) Combo Port The 5073E-T Switch has three auto-detected gigabit cooper/SFP ports, which are the Mini-GBIC Combo ports. These ports should use Category 5e (or above) UTP/STP cable for connections up to 1000 Mbps. The small form- factor pluggable (SFP) is a compact optical transceiver used in optical communications for both telecommunication and data communications.
Page 17
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual NOTE The SFP port and copper combo port cannot function at the same time. The SFP port has a higher priority than the copper port. If you insert the 1000 M SFP transceiver (which is connected to the remote device via fiber cable) into the SFP port, the connection of the accompanying copper port will link down.
Page 18
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual Figure 11 Remove LC Connector b. Pull out the plastic handle to release the transceiver, and then grasp the tranceiver and pull it out. Figure 12 Pull Transceiver Out of SFP Port www.cooperbussmann.com/wirelessresources...
Pro-Ring2se is a new ring mechanism for the Cooper Bussmann/ELPRO Technologies Industrial Ethernet Switches. As Figure 15 shows, Pro-Ring2se can be constructed using two ports of the same type in each 5073E-T. Refer to “6.5.5 Redundancy - Pro-Ring2se” for information on configuring each switch to enable the Pro-Ring2se feature.
Page 20
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual Figure 15 Pro-Ring2se Connection Examples www.cooperbussmann.com/wirelessresources Rev Version 1.1...
A RS-232 to RJ-45 connector cable is supplied with the switch (Figure 16). Connect the RS-232 connector to PC or terminal and the RJ-45 connector to the console port of the 5073E-T switch. The connected terminal or PC must support a terminal emulation program, such as HyperTerminal or PuTTY.
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual 5.3 Logging onto the Console Interface 1. After connecting the 5073E-T Switch to the PC, turn on the PC. For connection instructions, see “5.1 Connecting to the Console Port.” 2. Run the terminal emulation program (for example, HyperTerminal or PuTTY) and configure its communication parameters to match the following default characteristics of the console port.
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual 5.4 CLI Management The system supports the console management CLI commands. After logging on to the system, you will see a command prompt. To enter the CLI management interface, type the “enable” command. See “Appendix B - COMMAND SETS”...
6.1 Preparing for Web Management Before using the Web-based Management Utility, install the 5073E-T Switch on the network and make sure that all PCs on the network can connect with the switch through the Web browser. The default IP address, subnet mask, username, and password for the 5073E-T Switch are as follows: • IP Address: 192.168.1.88...
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual 6.3 Web Page Overview The Web-based Management Utility uses a standard Web interface with the menu on the left. Click to expand a menu, and click to collapse a menu. You can also expand or collapse the entire menu tree by clicking Open All or Close All.
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual Kernel Version Kernel software version. Device MAC Unique hardware address assigned by the manufacturer. System Time Current time on switch. Enable Location Alert Click to cause the fault LED on the switch to flash.
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual Figure 24 CPU Load Average Page Loading Average Displays the CPU load statistics. Event Alarm Setting Select the Syslog checkbox if you want an alarm to be logged to the Syslog when the CPU load exceeds 90% utilization.
Page 28
SNTP server. When disabled, local time is used without any SNTP server information. NOTE when SNTP is enabled, a network connection between the 5073E-T switch and the SNTP server is required for the SNTP client within the switch to receive and synchronize time information to the time provided by the SNTP server.
Page 29
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual Local Time Zone Conversion from UTC Time at 12:00 UTC EST - Eastern Standard -5 hours 7 am CDT - Central Daylight CST - Central Standard -6 hours 6 am MDT - Mountain Daylight...
Click to apply the settings. 6.4.4 IP Addressing – IPV4 The 5073E-T Switch needs to be assigned an IP address that identifies it on the network. You can select a method of assigning IP address to the switch by choosing System-->IP Addressing-->IPV4.
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual IP Address Enter a static IP address to the switch from the subnet address range that the network is using. If the DHCP Client option is enabled, the switch is configured as a DHCP client.
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual Syslog Log To display the current system event log (Figure 29), choose System-->Syslog-->Log. Click Reload or press F5 to refresh the page to view the most recent events. Figure 29 Log Page Reload Reloads the current log.
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual Figure 30 SNMP Agent Configuration Agent Mode Select the SNMP version (V1/V2c or V3) that you want to use. And then click Apply to switch to the selected SNMP version mode. SNMP V1/V2c...
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual • Digital input trap • Topology change trap Figure 31 SNMP - Trap (Trap Manager) Server IP Enter the IP address of the trap manager. Community Enter the community string for the trap station.
Page 35
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual management information items that can be accessed by an SNMPv3 entity. A context is identified by the SNMPv3 engine ID value of the entity hosting the management information (this can be found in System-->SNMP-->Agent) and a context name that identifies the specific context.
Page 36
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual Use the Group tab to configure the SNMPv3 group table The group name created in this tab is associated with the user ID. Both the group name and the user ID are used as parameters to create entries in the access table that appears in the Access tab.
Page 37
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual Use the Access tab to configure the SNMPv3 access table. The entries in this table define different access profiles. Each access profile can be identified by its context prefix and group name. An access profile is associated with a security level, context matching rule, and names of read, write, and modify MIB views.
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual Adds the new access profile. Remove Removes the access profile selected in the Current Access Tables list. Use the MIB View tab to configure the management information base (MIB) table. Figure 36 SNMPv3 MIB View Tab Current MIB Tables Lists the existing MIB views.
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual Figure 37 System Alert - Relay Alarm (Fault Relay Alarm) Power Failure Select the checkbox if you want the fault LED indicator on the panel to turn on when Setting power fails.
Click to apply the setting. Digital Input/Digital Output The 5073E-T Switch contains two digital outputs and two digital inputs. Outputs are open-collector transistor switches that may be controlled by the host computer. They provide control signals, which can be applied to heaters, pumps, and other electrical equipment.
Page 41
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual Figure 40 Digital Output To set digital input and digital output triggers, choose System-->System Alert-->DIDO to display the following page. Figure 41 Digital Input/Output Trigger Setting Digital Input Setting Enabling DI0 makes the first digital input available. Enabling DI1 makes the second digital input available.
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual Digital Input Choose the transition type to trigger DI0 or DI1: • Low-->High—When this option is selected, DI0/DI1 will only report the status when the voltage of the external device changes from low to high.
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual Figure 42 DHCP Server Configuration DHCP Server Enable or disable the DHCP server function on the switch. When enabled, the switch will be the DHCP server on your local network. Start IP Address Enter the IP address that is the beginning of the dynamic IP address range.
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual Figure 44 IP Binding Apply Click to apply the setting. 6.5 Configure Menu 6.5.1 Port Port Configuration To configure the settings of each port to control the connection parameters, choose Configure-->Port-- >Configuration. The status of each port is listed at the bottom of the page.
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual Speed/Duplex You can choose a port speed setting, or choose Auto Negotiation for the port to negotiate the speed. The port speed options vary depending on the port. For port 1-6 and port 8, the options are 100 FULL, 100 HALF, 10 FULL and 10 HALF.
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual Figure 47 Port Statistics Port Port number. Type Displays the current speed of connection to the port. Link Current link status: Up—Link is operational. Down—Link is not operational. State State set on the Port Configuration page (see “6.5.1 Port”). When the state is disabled, the port will not transmit or receive packets.
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual Figure 48 Port Alert Port Event For the Port Event menus to become available, the “Client Only” option in Syslog Configuration must be enabled (see “6.4.5 Syslog”). There are four port event options: • Link Up—The system will only issue a log message when the link-up event...
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual Figure 49 Rate Limit Egress Setting Allows you to set the egress rate limit (in kbps) for each port. Note that 1 Mbps is equal to 1024 kbps. The range is from 100 kbps to 102400 kbps (100 Mbps) for mega-ports, or 256000 kbps (250 Mbps) for giga-ports.
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual Ingress Limit Select the frame type to be filtered: Frame Type • All • Broadcast/Multicast/Flooded Unicast • Broadcast/Multicast • Broadcast only Broadcast/Multicast/Flooded Unicast, Broadcast/Multicast, and Broadcast only types are only for ingress frames. The egress rate only supports the “All” type.
In this configuration, if a working port fails, one of the non- working ports will be brought in to carry traffic in place of the failed working port. The 5073E-T Switch uses IEEE 802.3ad LACP protocol to negotiate an agreement with its member ports.
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual RSTP Settings The Spanning Tree - RSTP Settings page provides the bridge and port configuration interface for RSTP. You can assign a higher or lower priority to each port. When RSTP is enabled, the port with the higher priority is in the forwarding state and other ports are blocked to make certain there is no loop in the LAN.
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual The rapid state transitions possible within RSTP depend on whether the port concerned can only be connected to a specific bridge (it is served by a point-to-point LAN segment), or can be connected to two or more bridges (it is served by a shared medium LAN segment).
The number of seconds a port waits before changing from Rapid Spanning Tree Protocol learning and listening states to the forwarding state. 6.5.5 Redundancy - Pro-Ring2se To configure Pro-Ring2se function on the 5073E-T Switch, choose Configure-->Redundancy-->Pro-Ring2se. For examples of Pro-Ring2se connection options, see “4.1 Pro-Ring2se Application.” Figure 55 Pro-Ring2se Pro-Ring2se Enable or disable the Pro-Ring2se function.
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual Primary Port Any two ports from a switch can be chosen to build the ring topology. Secondary port NOTE Although any two ports of switch can be chosen for this option, the selected ports must be equipped with the same speed and the same type of interface as other switches in the same ring.
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual Message Description Leave Group A message sent by a host to the querier to indicate that the host has quit being a member of a specific multicast group. IGMP Snooping If the switch supports IP multicast, you can enable the IGMP protocol. To display this page, choose Configure-->Multicast Support-->IGMP Snooping.
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual To configure filtering, choose Configure-->Multicast Support-->Static Filtering. Figure 57 Static Filtering IP Address Assign a multicast group IP address in the range 224.0.0.0 to 239.255.255.255. Member Ports Select the port checkbox to include the port as a member in the specified multicast group IP address.
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual LLDP Protocol Enable or disable the LLDP function. LLDP Interval Set the interval (in seconds) for advertising the switch information to other nodes. Sync Time Enables or disables switch clock synchronization using LLDP.
VLAN Configuration To configure VLAN, choose Configure-->VLAN-->VLAN Configuration. The 5073E-T Switch supports two VLAN modes—802.1Q (tagged-based) VLAN, and port-based VLAN. These modes are described on the following pages. By default, VLAN operation is disabled.
Page 59
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual 802.1Q VLAN Mode—If you choose 802.1Q VLAN mode (Figure 62), you can see the link type, untagged VID, and tagged VID information of each port. Figure 62 VLAN Configuration - 802.1Q VLAN Operation Mode Select the VLAN operation mode, or disable VLAN.
Page 60
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual • IQ Trunk Link—This link type only supports multiple tagged VIDs. The IQ trunk link is a segment that provides the link path for one or more VLAN-aware devices (switches). A trunk port, connected to the trunk link, has an understanding of tagged frame, which is used for communication among VLANs across switches.
Page 61
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual Port Based VLAN Mode— Port Based VLAN mode provides a simple way to create a VLAN. To create a new port based VLAN, first choose “Port Based” in the Operation Mode field (see Figure 63), and then click Add. The screen now looks like Figure 64.
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual Figure 64 VLAN Configuration - Port-based VLAN (Step 2) Operation Mode Select the VLAN operation mode or disable VLAN. The following fields appear when you choose Port Based VLAN mode. Group Name Assign a name to the VLAN.
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual 6.5.10 QoS Quality of Service (QoS) allows you to assign a priority to various applications, users, or data flows, or guarantee a specific level of performance to a data flow. QoS guarantees are important if network capacity is insufficient, particularly for real-time streaming multimedia applications, such as voice-over-P and video teleconferencing.
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual Port Priority When the QoS Mode on the QoS - Global Settings page is set to “Port Based,” you can set the queuing policy for each port. To display the QoS Port Priority page, choose Configure-->QoS-->Port Priority.
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual COS Priority Select a COS priority level (high, middle, low, or lowest). COS Port Default Assign a default priority value to each port. A default priority is considered and determined by the ingress port when an ingress packet has no VLAN tag.
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual Figure 70 Mirroring Destination Port Set which switch port will be responsible for collecting the data that was duplicated from the source port. Source Port Set which switch port will have its data duplicated and sent to the destination port.
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual IP Security Mode Enable or disable IP security. When security is enabled, the fields on this page become active. Enable Web When this checkbox is selected, any device whose IP address matches one of the Management 10 IP addresses in the Security IP1–P10 table (see the next section) will be given...
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual 6.6.2 802.1X/Radius The IEEE authentication specification 802.1X prevents the client from accessing a wireless access point or wired switch until it provides security information, such as a user name and password, which is verified by an authentication server (for example, a RADIUS server).
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual Server Timeout Set the number of seconds that the switch waits for a server response to an authentication request. Max Requests Set the number of authentications that must time-out before authentication fails and the authentication session ends.
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual Figure 75 802.1X Radius - Port Status 6.6.3 MAC Filtering To block an unauthorized MAC address by switch, choose Security-->MAC Filtering. The MAC blacklist shows the list of MAC addresses that are currently blocked.
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual 6.6.4 Port Security To block (or unblock) a MAC address by port, choose Security-->Port Security. Figure 77 Port Security MAC Address Enter a MAC address that you want add or delete from the Port Security List.
Figure 80 Factory Defaults 6.7.4 Firmware Upgrade The firmware upgrade software image for the 5073E-T Switch can be obtained by contacting a Sales Representative. To upgrade the firmware from a TFTP server or a website, choose Maintenance-->Firmware Upgrade. Click the tab for the upgrade method you want to use.
You can back up (export) the current configuration from flash ROM to the TFTP server or a local computer connected to the 5073E-T Switch (see Figure 83). You can also recover (import) a previous backup configuration to restore the settings (see Figure 84). This saves having to manually reconfigure settings.
Page 74
To export a configuration file to a TFTP server, enter the TFTP server IP address and the backup file name, and then click Backup in the upper part of the Export tab. To export a configuration file to a local computer connected to the 5073E-T Switch, click Backup in the bottom part of the Export tab.
Restore in the upper part of the Import tab. To import a configuration file that was exported to a local computer connected to the 5073E-T Switch, use the Browse button to locate the backup file, and then click Restore in the bottom part of the Import tab.
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual To configure digital diagnostic monitoring (DDM) functions, choose Maintenance-->Diagnostics-->DDM. DDM enables you to monitor real-time parameters of the SFP ports and set whether the port logs alarm events to the Syslog on the switch.
Page 77
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual describe common problems you may encounter and indicate where you can find solutions. 4. If the power indicator does not turn on when the power cord is plugged in, you may have a problem with power cord.
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual a - rJ-45 pIN aSSIGNMENT ppENDIx The UTP/STP ports will automatically detect fast Ethernet (10Base-T/100Base-TXconnections), or Gigabit Ethernet (10Base-T/100Base-TX/1000Base-T connections). Auto MDI/MDIX means that the switch can connect to another switch or workstation without changing straight-through or crossover cabling. See the figures in this appendix for straight through and crossover cable schematics.
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual B - COMMaND SETS ppENDIx This appendix describes the command sets for the 5073E-T Managed Ethernet Switch. The commands are associated with a user level, described in the following key. E = User EXEC...
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual CLI Commands Level Description Example 8021x misc Use the 802.1x misc server timeout switch>enable servertimeout global configuration command to set switch#configure the server timeout. switch(config)#8021x misc [Seconds] servertimeout 20 8021x misc maxrequest Use the 802.1x misc max request...
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual CLI Commands Level Description Defaults/Example tftp Get configuration from TFTP server. switch>enable Need to specify the IP address of switch#configure [server IP] the TFTP server and the file name of switch(config)#tftp 192.168.1.120 image.
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual CLI Commands Level Description Example no ip dhcp Disable DHCP client function of switch>enable switch. switch#configure switch(config)#no ip dhcp LLDP Commands CLI Commands Level Description Example lldp enable Enable LLDP function. switch>enable...
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual Ping Command CLI Commands Level Description Example ping Ping function. switch>ping 192.168.1.1 [ip] Port Control Commands CLI Commands Level Description Example interface fastEthernet Choose the port for modification. switch>enable switch#configure [Portid] switch(config)#interface fastEthernet 2...
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual CLI Commands Level Description Example alias Set port alias name. switch>enable switch#configure [name] switch(config)#interface fastEthernet 2 switch(config-if)#alias 1111 show interface Show interface configuration status. switch>enable configuration switch#configure switch(config)#interface fastEthernet 2 switch(config-if)#show interface...
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual CLI Commands Level Description Example no mac-address-table Remove an entry from the MAC switch>enable static hwaddr address table of interface (static). switch#configure [HW-Addr] switch(config)#interface fastEthernet 2 switch(config-if)#no mac-address- table static hwaddr 000012345678...
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual Save Configuration Command CLI Commands Level Description Example write memory Save user configuration into switch>enable permanent memory (flash ROM). switch#write memory SFP Monitor Command CLI Commands Level Description Example show ddm Show temperature alarm information.
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual SNTP Commands CLI Commands Level Description Example sntp enable Enable the SNTP function. switch>enable switch#configure switch(config)#sntp enable sntp ip Set the SNTP server IP address. switch>enable If the SNTP function is inactive, this...
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual CLI Commands Level Description Example system description Set switch system description string. switch>enable switch#configure [System Description] switch(config)#system description xxx system contact Set switch system contact window switch>enable string. switch#configure [System Contact] switch(config)#system contact xxx show system-info Show system information.
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual Trunk Commands CLI Commands Level Description Example aggregator priority Set port group system priority. switch>enable switch#configure [1–65535] switch(config)#aggregator priority 22 aggregator group Assign a trunk group with LACP switch>enable active. switch#configure [GroupID] [Port-list] switch(config)#aggregator group 1 [GroupID]: 1–3...
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual VLAN Commands CLI Commands Level Description Example vlan database Enter VLAN configure mode. switch>enable switch#vlan database vlanmode Set switch VLAN mode. switch>enable switch#vlan database [portbase| 802.1q | switch(vlan)#vlanmode portbase disable| gvrp] switch(vlan)#vlanmode 802.1q...
Page 99
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual CLI Commands Level Description Example vlan 8021q port Assign a trunk link for VLAN by port. switch>enable [PortNumber] If the port belongs to a trunk group, switch#vlan database this command cannot be applied.
Page 100
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual CLI Commands Level Description Example show vlan Show VLAN information. switch>enable [GroupID] switch#vlan database switch(vlan)#show vlan 2 show vlan no vlan Delete port base group ID. switch>enable [GroupID] switch#vlan database switch(vlan)#no vlan 2 www.cooperbussmann.com/wirelessresources...
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual C - GLOSSarY ppENDIx Term Definition American wire gauge (AWG), also known as the Brown & Sharpe wire gauge, is a standardized wire gauge system used predominantly in the United States and Canada for the diameters of round, solid, nonferrous, electrically conducting wire.
Page 102
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual Term Definition Internet protocol. A set of rules used to send and receive messages across local networks and the Internet. IP Address A 32-bit number that identifies each sender or receiver of information that is sent across the Internet.
Page 103
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual Term Definition SNMP Simple Network Management Protocol (SNMP) is an Internet-standard protocol for managing devices on IP networks. Devices that typically support SNMP include routers, switches, servers, workstations, printers, modem racks and so on. It is used mostly in network management systems to monitor network-attached devices for conditions that warrant administrative attention.
Page 104
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual Term Definition Wi-Fi Wireless Fidelity. An interoperability certification for wireless local area network (LAN) products based on the Institute of Electrical and Electronics Engineers (IEEE) 802.11 standard. www.cooperbussmann.com/wirelessresources Rev Version 1.1...
Page 105
Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual Notes www.cooperbussmann.com/wirelessresources Rev Version 1.1...