Amana AMV8 Installation Instructions Manual page 35

Tw-stage gas-fired warm air furnace
Table of Contents

Advertisement

Wiring Diagram - ADV8
BK
16 W I RE HARNESS
BR
24 VAC. HUM .
RD
BR
BL
PU
BK
W H
RD
BL
I NDUCTOR COI L
ON SOM E M ODELS
YL
RD
W H
I NDUCED
OR
BLOW ER
YL
BL
1 5
1 4
1 3
1 2
1 1
1 0
9
8
7
6
5
4
3
2
1
BK
BK
DOOR SW I TCH
AUXI LI ARY
LI M I T CONTROL
CI RCULATOR
BLOW ER
CONTROL
PANEL
JUNCTI ON BOX
LI NE- N
W H
SEE
GND
NOTE 5
LI NE H
TO 115 VAC/ 1/ 60HZ
POW ER SUPPLY W I TH
OVERCURRENT PROTECTI ON
DEVI CE
HI FI RE
PRESSURE SW I TCH
W 1
24
W 2
VAC.
BR
HUM .
Y
LOW FI RE
G
BR
C
PRI M ARY
LI M I T CONTROL
RD
PU
I NTEGRATED CONTROL M ODULE
++ - USE NEC CLASS 2 W I RE
35
SEE
NOTE 5
DI SCONNECT
DOOR
SW I TCH
J UNCTI ON BOX
I NDUCTOR COI L
90kBTU, 115 KBTU
M ODELS ONLY
I NDOOR
AI R
CI RCULATOR
BLW R
LI NE- H
EAC- H
EAC- N
ELECTRONI C
AI R CLEANER
I ND HI
I ND- N
I D
BLW R
I ND LO
HUM - H
HUM - N
HUM I DI FI ER
I GN- H
I GN- N
HOT SURFACE
I GNI TER
FP ( 3)
FLAM E SENSOR
XFM R- H
115 VAC
40 VA
TRANSFORM ER
TH ( 5)
R
P R I M A R Y LI M I T
C O N TR O L
HLO ( 11)
M AN U A L R ES ET R O LLO U T
LI M I T C O NTR O L
HL1 ( 6)
TO
M I CRO
24V HUM .
PS1 ( 12)
NO
A U X I LI A R Y LI M I T
C O N TR O L
M VL( 7)
M VH ( 1)
NO
C
PS2 ( 2)
HI GH FI RE
M VC ( 8)
PRESSURE SW I TCH
GND ( 4)
TR ( 9)
LI NE- N
XFM R- N
C
LOW FI RE
PRESSURE
SW I TCH
PM
HI
C
GAS
VALVE