Full One Year Warranty

D
WALT heavy duty industrial tools are warranted for one year from
e
date of purchase. We will repair, without charge, any defects due
to faulty materials or workmanship. For warranty repair information,
call 1-800-4-D
WALT (1-800-433-9258). This warranty does not
e
apply to accessories or damage caused where repairs have been
made or attempted by others. This warranty gives you specific legal
rights and you may have other rights which vary in certain states or
provinces.
lAtIn AMerICA: This warranty does not apply to products sold
in Latin America. For products sold in Latin America, see country
specific warranty information contained either in the packaging, call
the local company or see website for warranty information.
Free WArnInG lABel rePlACeMent: If your warning
labels become illegible or are missing, call 1-800-4-D
(1-800-433-9258) for a free replacement.
DRAIN TANK DAILY
OR AFTER EVERY 4 HOURS OF USE. CONDENSATION BUILD-UP MAY CAUSE
WARNING
CORROSION INSIDE TANK RESULTING IN TANK FAILURE. SEE MANUAL FOR INSPECTION PROCEDURES.
TO DRAIN TANK OPEN VALVE SLOWLY AND TILT COMPRESSOR TO EMPTY ACCUMULATED WATER.
DRENE EL TANQUE A DIARIO O DESPUÉS DE CADA 4 HORAS DE USO. LA ACUMULACIÓN DE
ADVERTENCIA
CONDENSACIÓN PUEDE OCASIONAR CORROSIÓN DENTRO DEL TANQUE Y PROVOCAR FALLA DEL
TANQUE. CONSULTE EL MANUAL PARA CONOCER LOS PROCEDIMIENTOS DE INSPECCIÓN. PARA DRENAR EL TANQUE, ABRA LA
VÁLVULA LENTAMENTE E INCLINE EL COMPRESOR PARAELIMINAR EL AGUA ACUMULADA.
RÉSERVOIR DE VIDANGE QUOTIDIEN OU APRÈS TOUTES LES 4 HEURES D'UTILISATION.
AVERTISSEMENT
L'HABILLAGE DE CONDENSATION PEUT CAUSER LA CORROSION À L'INTÉRIEUR DU RÉSERVOIR AYANT
POUR RÉSULTAT L'ÉCHEC DE RÉSERVOIR. VOIR LE MANUEL POUR DES PROCÉDURES D'INSPECTION. À LA VALVE
OUVERTE DE RÉSERVOIR DE VIDANGE LENTEMENT ET AU COMPRESSEUR D'INCLINAISON À L'EAU ACCUMULÉE VIDE.
WARNING
WARNING
HOT SURFACES
DO NOT ADJUST FACTORY SETTINGS.
TO REDUCE RISK OF ELECTRIC SHOCK
ADVERTENCIA
SUPERFICIES CALIENTES
DO NOT REMOVE COVER.
Pressure controls set at factory for
maximum safe operation.
AVERTISSEMENT
ADVERTENCIA
SURFACES CHAUDES
NO HAGA CAMBIOS EN LOS AJUSTES
DE FÁBRICA. NO RETIRE LA TAPA PARA
REDUCIR EL RIESGO DE CHOQUE ELÉCTRICO.
Los controles de presión se ajustan en la
fábrica para máxima seguridad en la operación.
AVERTISSEMENT

GLOSSArY

CFM: Cubic feet per minute.
sCFM: Standard cubic feet per minute; a unit of measure of air
delivery.
PsI: Pounds per square inch; a unit of measure of pressure.
Code Certification: Products that bear one or more of the
following marks: UL
®
by OSHA certified independent safety laboratories and meet the
applicable Standards for Safety.
* UL
is a registered trademark of Underwriters Laboratories
®
and ETL
is a registered trademark of Electrical Testing
®
Laboratories.
WALT
Cut-In Pressure: While the motor is off, air tank pressure drops
e
when accessory is used. When the tank pressure drops to a certain
low level the motor will restart automatically. The low pressure at
which the motor automatically restarts is called cut-in pressure.
Cut-Out Pressure: When an air compressor is turned on and
begins to run, air pressure in the air tank begins to build. It builds
to a certain high pressure before the motor automatically shuts
off, protecting your air tank from pressure higher than its capacity.
The high pressure at which the motor shuts off is called cut-out
pressure.
Branch Circuit: The circuit carrying electricity from electrical
panel to outlet.
Duty Cycle: This air compressor pump is capable of running
continuously. However, to prolong the life of your air compressor,
it is recommended that a 50%-75% average duty cycle be
maintained; that is, the air compressor pump should not run more
than 30-45 minutes in any given hour.