SERIAL Terminals Connection

The SERIAL terminal is used when this Display is controlled by
a computer.
[RS-232C]
NOTES:
Use the RS-232C cross cable to connect the computer to
this Display.
The computer shown is for example purposes only.
Additional equipment and cables shown are not supplied
with this set.
The SERIAL terminal conforms to the RS-232C interface
specification, so that this Display can be controlled by a
computer which is connected to this terminal.
The computer will require software which allows the sending
and receiving of control data which satisfies the conditions
given below. Use a computer application such as programming
language software. Refer to the documentation for the computer
application for details.
Basic format for control data:
The transmission of control data from the computer starts with Header byte, followed by the command, the parameters, and
lastly byte of checksum in that order. If there are no parameters, then the parameter signal does not need to be sent.
Header MonitorID Category
0xA6
0~26
0x00
NOTES:
Multiple commands are transmitted, be sure to wait for the response for the first command to come from this unit before
sending the next command.
If an incorrect command is sent by mistake, this unit will send an "ERROR" command back to the computer.
Command:
Command
Parameter
0x19
None
0x18
0x01
0x18
0x02
0x45
None
0x44
0~100
0xAC
0x01, 0x00, 0x00, 0x00
0xAC
0x03, 0x00, 0x00, 0x00
0xAC
0x09, 0x01, 0x00, 0x00
0xAC
0x09, 0x00, 0x00, 0x00
0xAC
0x05, 0x00, 0x00, 0x00
0x3B
None
0x3A
0x00
0x3A
0x01
0x3A
0x02
0x3A
0x03
18
Display No.1
Code0
Code1
Length
Control
0x00
0x00
N+3
Control Details
Get Power State
POWER OFF
POWER ON
Get Volume
Set Volume
Change source to VIDEO
Change source to DVD/HD
Change source to DVI
Change source to HDMI
Change source to PC
Get picture format
Change picture format to Normal
Change picture format to Custom
Change picture format to Real
Change picture format to Full
Signal names for SERIAL IN terminal:
1
2
6
These signal names are those of computer specifications.
Communication parameters:
Signal level
Synchronization method
Baud rate
Parity
Character length
Stop bit
Flow control
Data[0]
Data[1]
~
0x01
Command
Parameter
Pin No. Signal Name
1
2
3
3
4
5
4
5
7
8
9
6
7
8
9
RS-232C compliant
Asynchronous
9600 bps
None
8 bits
1 bit
-
Data[N]
The total from Header to Data[N] calculated by XOR
DCD
RXD
TXD
DTR
GND
DSR
RTS
CTS
RI
Checksum

Advertisement