This appliance may be placed on a smooth combustible or noncombustible continuous, flat surface. When the appliance is installed
directly on carpeting, tile or other combustible material other than wood flooring, the appliance shall be installed on a metal or wood
panel extending the full width and depth of the appliance. Slide the appliance into position and level the appliance from side-to-side and
front-to-back. Shim with noncombustible material as necessary.
Secure the appliance by bending out the nailing flanges on each side of the appliance and nail to framing. The nailing flanges have
been positioned 5/8 inch back from the front of the appliance to allow the addition of drywall.
The Novus Plus must be power vented with the HRV200PLUS and must not be connected to a chimney flue.
Refer to the HRV200PLUS installation manual for proper venting configurations for the Novus Plus gas appli-
ance.
6
D. SETTING THE APPLIANCE
WARNING!
E. VENTING
WARNING!
4031-478 Rev i
NOVUS PLUS INSTALLATION INSTRUCTIONS
11/04