INSTALLING THE BLOWER
Remove the blower housing from the back of the
Figure 8.13
appliance by removing the four corner screws.
Snap disc
Magnetic strips
Gently pull housing away from the appliance expos-
Figure 8.14
ing the junction box and the magnet strips that the blower will
sit on. Position the blower between the tabs inside the blower
housing. The magnet strips located on the blower feet are
designed to hold the blower in place.
Plug the blower cord into the blower receptacle FAN on the
junction box. Attach the ground wire to the bottom of the
junction box.
Remove the knob and locknut from the variable
Figure 8.15
speed control. Slide the control onto the valve bracket located
on the upper right corner on the back of the appliance with the
back of the stem sticking out of the pre-punched hole. Attach
the locknut tightly and reattach the knob on the stem.
July 12, 2006
Slide the temperature sensor switch/bracket assembly onto
the machine screw located inside the pedestal. Secure the
bracket assembly with the wing nut provided.
NOTE: THE SWITCH/BRACKET ASSEMBLY MUST BE
INSTALLED SO THAT THE SENSOR SWITCH MAKES
CONTACT WITH THE BOTTOM OF THE FIREBOX.
Connect the variable speed control and the temperature
sensor switch to the short lead wires of the junction box by
plugging in the male and female connectors. See Fig. 8.16,
on the next page (Fan Wiring Diagram).
Turn the 110-120 VAC service "ON" at the circuit breaker
and turn the speed control switch to the "ON" position.
RECOMMENDED OPERATING PROCEDURES
Ignite the fire in the appliance with the variable speed control
switch in an "ON" position. The fan will automatically turn on
when the temperature sensor switch closes at approximately
110 degrees Fahrenheit. Heated air should be delivered at
the outlet grille. The fan will continue to operate after the
appliance is turned OFF until the sensor switch opens.
Various conditions (such as appliance model, type of
appliance installation, outside air temperature vs. inside air
temperature) can contribute to the length of the time the
blower remains on after the appliance is turned OFF. The
blower can be turned off manually with the speed control
switch.