FCC Statement This equipment uses, and can radiate radio frequency energy that may cause in- terference to radio communications if not installed in accordance with this man- ual. The equipment has been tested and found to comply with the limits of a Class A computing device pursuant to Subpart J, Part 15 of FCC Rules which are designed to provide reasonable protection against such interference when op- erated in a commercial environment.
Aud iocom ® Description The PS2000L is a versatile power supply that can be used in a variety of Audiocom® intercom system applications. It directly accepts any AC input power from 100 to 240 VAC, 50/60 Hz, and it can be configured to power two separate intercom channels or one large intercom channel with twice the intercom station capacity.
Page 5
2. Channel Status Indicators and Reset Pushbutton: The indicators are green for nor- mal operation and red when there is an overload or short circuit. The Reset push- button restores normal operation after the short-circuit or overload has been located and fixed. 3.
The package contains the following items. Contact the shipper or your Audiocom dealer immediately if anything is damaged or missing. Detach and fill out the regis- tration card and return it to Telex to properly register your PS2000L. Quantity Description...
Figure 2. Audiocom / Clear-Com Selector Switch (Top Cover Removed) Intercom Channel Connections Channel Capacity: When connecting intercom stations to the PS2000L, determine the total current for all stations on each channel. The total per channel should not ex- ceed 2A. If you exceed this limit, the PS2000L will provide an overload indication. Note that if you are using DC wallpacks with any intercom stations, you do not need to add the current consumption of those stations to the total current.
Aud iocom ® Figure 5. Using two PS2000L Power Supplies to provide a greater capacity on each channel. Power-Up Check Plug in any DC wallpacks that are being used with individual intercom stations. If you plug in DC wallpacks after applying power to the PS2000L, you may get an overload indication at the PS2000L.
Specifications General Input Power Requirements: 100 to 240 VAC, 50 / 60 Hz Output Power (each channel) 21 ± 1 VDC, 2A Dimensions: 1.75" (44.5 mm) high x 8.25" (209.5 mm) wide x 10.31" (261.9 mm) deep Weight: approximately 2.5 lb (1.13 kg) Environmental Requirements: Storage: -20°C to 80°C;...