Download Print this page

Casio 4335 Operation Manual page 4

Casio watch operation guide

Advertisement

Operation Guide 4335 4348
About the Auto Light Switch
Turning on the auto light switch causes illumination to turn on, whenever you position
your wrist as described below in any mode, except for the Hand Setting Mode setting
screen.
Moving the watch to a position that is parallel to the ground and then tilting it towards
you more than 40 degrees causes illumination to turn on.
• Wear the watch on the outside of your wrist.
Parallel to
ground
Warning!
• • • • • Always make sure you are in a safe place whenever you are reading the
display of the watch using the auto light switch. Be especially careful when
running or engaged in any other activity that can result in accident or injury.
Also take care that sudden illumination by the auto light switch does not
startle or distract others around you.
• • • • • When you are wearing the watch, make sure that its auto light switch is turned
off before riding on a bicycle or operating a motorcycle or any other motor
vehicle. Sudden and unintended operation of the auto light switch can create a
distraction, which can result in a traffic accident and serious personal injury.
To turn the auto light switch on and off
In the Timekeeping Mode, hold down D for about three seconds to toggle the auto
light switch on (
displayed) and off (
• The auto light switch on indicator (
) is on the display in all modes while the auto
light switch is turned on.
• In order to protect against running down the battery, the auto light switch will turn off
automatically approximately six hours after you turn it on. Repeat the above
procedure to turn the auto light switch back on if you want.
Reference
This section contains more detailed and technical information about watch operation.
It also contains important precautions and notes about the various features and
functions of this watch.
Moon Phase Indicator
The Moon phase indicator of this watch indicates the current phase of the Moon as
shown below.
Moon phase indicator
Module 4335
(part you cannot see)
Moon
Module
Phase
4335
Indicator
Module
4348
0.0 - 1.8 1.9 - 5.5 5.2 - 9.2 9.3 - 12..9 13.0 - 16.6 16.7 - 20.2 20.3 - 23.9 24.0 - 27.6
Moon Age
27.7 - 29.5
First
New
Moon Phase
Moon
Quarter
(Waxing)
• The Moon phase indicator shows the Moon as viewed at noon from a position in the
Northern Hemisphere looking south. Note that at times the image shown by the
Moon phase indicator may differ from that of the actual Moon in your area.
• The left-right orientation of the Moon phase is reversed when viewing from the
Southern Hemisphere or from a point near the equator.
Moon Phases and Moon Age
The Moon goes through a regular 29.53-day cycle. During each cycle, the Moon
appears to wax and wane as the relative positioning of the Earth, Moon, and Sun
changes. The greater the angular distance between the Moon and the Sun,* the more
we see illuminated.
* The angle to the Moon in relation to the direction at which the Sun is visible from the
Earth.
This watch performs a rough calculation of the current Moon age starting from day 0
of the moon age cycle. Since this watch performs calculations using integer values
only (no fractions), the margin for error of the displayed Moon age is ± 1 day.
Tide Graph
The wave on the watch's tide graph indicates the current tide.
Tidal Movements
Tides are the periodic rise and fall of the water of oceans, seas, bays, and other
bodies of water caused mainly by the gravitational interactions between the Earth,
Moon and Sun. Tides rise and fall about every six hours. The tide graph of this watch
indicates tidal movement based on the Moon's transit over a meridian and the lunitidal
interval. The lunitidal interval differs according to your current location, so you must
specify a lunitidal interval in order to obtain the correct tide graph readings.
The tide graph displayed by this watch is based on the current Moon age.
Remember that the margin for error of the Moon age displayed by this watch is ± 1
day. The greater the error in a particular Moon age, the greater the error in the
resulting tide graph.
More than
40°
not displayed).
Module 4348
Moon phase (part you can see)
Full
Last
Moon
Quarter
(Waning)
High tide
Low tide
Lunitidal Interval
Theoretically, high tide is at the Moon's transit over the meridian and low tide is about
six hours later. Actual high tide occurs somewhat later, due to factors such as
viscosity, friction, and underwater topography. Both the time differential between the
Moon's transit over the meridian until high tide and the time differential between the
Moon's transit over the meridian until low tide are known as the "lunitidal interval."
When setting the lunitidal interval for this watch, use the time differential between the
Moon's transit over the meridian until high tide.
Thermometer
Temperature Sensor Calibration
The temperature sensor built into the watch is calibrated at the factory and normally
requires no further adjustment. If you notice serious errors in the temperature readings
produced by the watch, you can calibrate the sensor to correct the errors.
Important!
Incorrectly calibrating the temperature sensor can result in incorrect readings.
Carefully read the following before doing anything.
• Compare the readings produced by the watch with those of another reliable and
accurate thermometer.
• If adjustment is required, remove the watch from your wrist and wait for 20 or 30
minutes to give the temperature of the watch time to stabilize.
To calibrate the temperature sensor
1. In the Timekeeping Mode, hold down A until the
seconds start to flash, which indicates the setting
screen.
2. Press C nine times to display the temperature sensor
calibration screen.
3. Use D (+) and B (–) to change the calibration value.
• You can change the value in 0.1ºC (0.2ºF) steps, in a
range of ±10ºC (±18ºF). The calibration value shows
Calibration value
''--.-'' when the setting is outside the allowable range.
• To return the calibration value to its default (no calibration, indicated by ''- -''),
press D and B at the same time.
• Temperature sensor calibration will not be possible if the current reading is
outside the allowable display range (–10.0°C/14.0°F to 60.0°C/140.0°F) and the
calibration value shows ''- -''.
• Setting a sensor calibration value does not affect temperature values that are
already stored in memory.
4. After configuring the setting you want, press A twice to exit the setting screen.
To specify the temperature display unit
1. In the Timekeeping Mode, hold down A until the
seconds start to flash, which indicates the setting
screen.
2. Press C 10 times to display the temperature unit
setting screen.
3. Use D to switch between Celsius (°C) and Fahrenheit
(°F).
• The initial factory default and the initial default after
Temperature unit
battery replacement is Celsius (°C).
4. After configuring the setting you want, press A twice to exit the setting screen.
• The temperature display unit setting you select is also applied to temperature values
that are already stored in memory.
Auto Return Feature
• If you leave a screen with flashing digits on the display without performing any
operation for two or three minutes, the watch saves any settings you have made up
to that point and exits the setting screen automatically.
• The watch will change to the Timekeeping Mode automatically if you do not perform
any operation in the Tide/Moon Data Mode, Temperature Data Recall Mode, Alarm
Mode, or Hand Setting Mode for two or three minutes.
Button Operation Tone
In any mode (except when a setting screen is on the display), hold down C for about
three seconds to toggle the button operation tone on and off. The button operation
tone off indicator ( ) is displayed while the tone is turned off.
• Even if the button operation tone is turned off, the daily alarm and countdown timer
alarm continue to sound when required.
Data and Setting Scrolling
The B and D buttons are used in various modes and setting screens to scroll
through data on the display. In most cases, holding down these buttons during a scroll
operation scrolls through the data at high speed.
Timekeeping
• Resetting the seconds to 00 while the current count is in the range of 30 to 59
causes the minutes to be increased by 1. In the range of 00 to 29, the seconds are
reset to 00 without changing the minutes.
• With the 12-hour format, the P (PM) indicator appears on the display for times in the
range of noon to 11:59 p.m. and the A (AM) indicator appears for times in the range
of midnight to 11:59 a.m.
• With the 24-hour format, times are displayed in the range of 0:00 to 23:59, without
any indicator.
• The year can be set in the range of 2000 to 2099.
• The watch's built-in full automatic calendar makes allowances for different month
lengths and leap years. Once you set the date, there should be no reason to change
it except after you have the watch's batteries replaced.
World Time
• The seconds count of the World Time is synchronized with the seconds count of the
Timekeeping Mode.
• All World Time Mode times are calculated from the current time in the Timekeeping
Mode using UTC time differential values.
• The UTC differential is a value that indicates the time difference between a
reference point in Greenwich, England and the time zone where a city is located.
• The letters UTC is the abbreviation for Coordinated Universal Time, which is the
world-wide scientific standard of timekeeping. It is based upon carefully maintained
atomic (cesium) clocks that keep time accurately to within microseconds. Leap
seconds are added or subtracted as necessary to keep UTC in sync with the Earth's
rotation.
4