F
A
F
URNACE
DVANCED
EATURES
Submenu Item
Number of Heat Stages (HT STG)
Input Rate (BTU/HR)
Motor HP (1/2, ¾, or 1 MTR HP)
Submenu Item
Fault 1 (FAULT #1)
Fault 2 (FAULT #2)
Fault 3 (FAULT #3)
Fault 4 (FAULT #4)
Fault 5 (FAULT #5)
Fault 6 (FAULT #6)
Clear Fault History (CLEAR)
NOTE: Consecutively repeated faults are shown a maximum of 3 times.
Submenu Item
Model Number (MOD NUM)
Serial Number (SER NUM)
Software (SOFTWARE)
Submenu Item
Heat Airflow Trim (HT TRM)
Heat ON Delay (HT ON
Heat OFF Delay (HT OFF)
Heat Airflow (HT ADJ)
Submenu Item
Mode (MODE)
CFM (CFM
M
ENUS
CONFIGURATION
Displays the number of furnace heating stages
Displays the furnace input rate in kBtu/hr
Displays the furnace indoor blower motor horsepower
DIAGNOSTICS
Indication/User Modifiable Options
Most recent furnace fault
Next most recent furnace fault
Next most recent furnace fault
Next most recent furnace fault
Next most recent furnace fault
Lease recent furnace fault
NO or YES
IDENTIFICATION
User Modifiable Options
-15% to +15% in 3% increments,
default is 0%
5, 10, 15, 20, 25, or 30 seconds,
default is 30 seconds
30, 60, 90, 120, 150, or 180 seconds,
default is 150 seconds
1, 2, 3, or 4
Indication (for Display Only; not User Modifiable)
Displays the current furnace operating mode
Displays the airflow for the current operating mode
Indication (for Display Only; not User Modifiable)
Indication (for Display Only; not User Modifiable)
Displays the furnace model number
Displays the furnace serial number (Optional)
Displays the application software revision
SET-UP
Trims the heating airflow by the selected
amount.
Selects the indoor blower heat ON delay
Selects the indoor blower heat OFF delay
Selects the nominal heating airflow (see
Section XIV, Startup Procedure and
Adjustment – Circulator Blower Speeds for
addition information)
STATUS
46
Comments
For display only
For display only
For display only
For display only
For display only
For display only
Selecting "YES" clears the fault
history
Comments