LG-Nortel LNES24 User Manual page 8

Fast ethernet switch
Table of Contents

Advertisement

France and Peru only
This unit cannot be powered from IT
be powered by 230 V (2P+T) via an isolation transformer ratio 1:1, with the secondary connection
point labelled Neutral, connected directly to earth (ground).
Impédance à la terre
Power Cord Set
U.S.A. and Canada
The cord set must be UL-approved and CSA certified.
The minimum specifications for the flexible cord are: - No. 18
AWG - not longer than 2 meters, or 16 AWG. - Type SV or SJ -
3-conductor
The cord set must have a rated current capacity of at least 10A.
The attachment plug must be an earth-grounding type with
NEMA 5-15P (15 A, 125 V) or NEMA 6-15P (15 A, 250 V)
configuration.
Denmark
The supply plug must comply with Section 107-2-D1, Standard
DK2-1a or DK2-5a.
Switzerland
The supply plug must comply with SEV/ASE 1011.
U.K.
The supply plug must comply with BS1363 (3-pin 13 A) and be
fit-ted with a 5 A fuse which complies with BS1362.
The mains cord must be <HAR> or <BASEC> marked and be
of type HO3VVF3GO.75 (minimum).
Europe
The supply plug must comply with CEE7/7 (.SCHUKO.).
The mains cord must be <HAR> or <BASEC> marked and be
of type HO3VVF3GO.75 (minimum).
IEC-320 receptacle.
supplies. If your supplies are of IT type, this unit must
.
vii