State Water Heaters GS6 40 YBDS Specifications page 2

Direct-vent residential gas water heaters

Advertisement

SELECT
Residential Gas Water Heaters
FIRST
ENERGY
MODEL
HOUR
FACTOR
NUMBER
RATING
GS6 40 YBDS
73
0.62
GS6 50 YBDS
87
0.60
GS6 50 YRDS
88
0.59
GS6 75 YRDS
131
0.59
Recoveries are rounded to nearest gallon
Water Connections - 3/4" on all models
**
Dual-channel system has 3" vent pipe inside 6" air intake pipe for the 40 & 50-gallon. The 75-gallon models uses a 4" x 7" Co-Axial pipe.
***
A dimension is to center line of flue (recommended vent height)
When ordering Propane, change "Y" to "H" in model number (GS6 40 HBDS)
All models have 2" foam cavity
75-gallon water connections are 12" on center.
Important! Vent Installation and Termination Requirements
• Maximum horizontal vent distance is 80" to outside of exterior wall.
• Minimum horizontal vent distance is 17" to outside of exterior wall.
• Vent pipes may be trimmed (cut) for short vent installations.
• For vent installation less than 30" the vent restrictor is required. Place
restrictor over the flue outlet on heater before installing the outlet vent
pipe to the heater.
• Recommended installation height for the heater and vent pipe should be
68" for 40-gallon models and 76" for the 50 and 75-gallon models (vent
height).
• Offset Vent Arrangement
1. When replacing an existing direct vent model, the new vent pipe may drop
from the minimum vent height as much as 7 1/4" to exit through the
existing vent opening in the exterior wall.
2. Vent may have one horizontal 90 degree turn before exiting through
exterior wall (Do not combine both offset vent arrangements in one
installation) (See examples in the installation manual)
• High Rise Vent Arrangement
3. When vent termination is more than 80" above the base of the heater.
The horizontal vent run must be a minimum of 22" from the center of the
heater to the outside exterior wall surface. (See example in the
installation manual)
• Vent termination clearance hole through the exterior wall should be
approximately 7" diameter.
• Snow accumulation and drifting should be considered when locating the
termination.
• An optional wire grill vent cap protector is available through the parts
department. Request part number 9006627.
• See the installation manual for complete installation and venting
requirements.
For complete information on limited warranties,
consult written warranty, or contact the State
Customer Care Center, 1-800-365-0024.
®
For more information on Select
contact:
State Water Heaters
500 Tennessee Waltz Parkway, Ashland City, TN 37015
800-365-0024 Toll-free USA
www.statewaterheaters.com
SRGSS02207
May 2008R
DIRECT-VENT
RECOVERY
BTU
GALLON
90 DEGREE
CAP
INPUT
RISE
38,000
41
40
50
42,000
45
50,000
55
50
75
55,000
60
A
B
R E S I D E N T I A L
DIMENSIONS
***
D
A
B
C
68
54-3/4
22-1/4
16
76
63-3/4
22-1/4
16
76
64-3/4
22-1/4
16-1/4
26-1/4
16-1/4
65-3/4
76
MIN VENT
17
MAX VENT
80
6" DIA. ON 40 & 50-GALLON MODELS
7" DIA. ON 75-GALLON MODELS
C
F
D
E
FRONT
VENT
SHIPPING
PIPE
**
WEIGHT
E
F
167
12-1/4
45-1/4
Co-Axial
12-1/4
54
Co-Axial
185
187
12-1/2
55-1/2
Co-Axial
55-1/2
12-1/2
Co-Axial
310
25-1/4 for
40 & 50-gallon
29-1/2 for
75-gallon
42°
47°
TOP
75-GALLON VENT
TERMINATION CAP
INTERCHANGEABLE
WITH THE VENT
40 & 50-GALLON
EXTERIOR
WALL
IS NOT
CAP ON THE
MODELS.

Advertisement

loading

This manual is also suitable for:

Gs6 50 yrdsGs6 75 yrdsSelect gs6 40 ybdsSelect gs6 75 yrdsGs6 50 ybpdt