Clearances - Heat & Glo HST-48D Owner's Manual

Wood burning fireplace
Hide thumbs Also See for HST-48D:
Table of Contents

Advertisement

B. Clearances
WARNING! Risk of Fire! You must comply with all minimum air space clearances to combustibles as specified in Fig-
ure 6.2. DO NOT pack required air spaces with insulation or other materials.
Storm Collar
Roof Flashing
(attic)
(insulation)
2 in. (51 mm) min.
Ceiling Firestop
48 in.
1219 mm
Figure 6.2
Clearances to Combustible Materials
Note: Chimney air kit and 11-10 in./279-254 mm adapter are not shown,
but are required in Canada.
Heat & Glo • HST-48D US-CAN • 4012-040 • Rev K• 3/12
Shaded areas
represent
2 in. (51 mm) min.
air space clearance
required around pipe
(ceiling)
Offset/Return (secured
with hanger straps)
(ceiling)
Adapter
0 in. to level
of standoffs
0 in.
to floor
Attic
Insulation
Shield
Must have 2 in. (51 mm)
minimum clearance
to header
1/2 in. (13 mm) to
sides of appliance
19