Hydro-Smart 170 Installation Manual And Owner's Manual

Hydro-Smart 170 Installation Manual And Owner's Manual

Micro boiler for radiant heating

Advertisement

Hydro-Smart 170
Micro Boiler for Radiant Heating
Installation Manual and Owner's Guide
Hydro-Smart 170
Please make sure the proper gas pressure guidelines and recommendation
from Hydro-Smart failure to do so can cause a fire or explosion and may
result, causing property damage, personal injury, or death.
WARNING
This product must be installed and
serviced by a licensed plumber, a
licensed gas fitter, or a professional
service technician. This product is for
radiant heating only and must be
installed in
with a combination of
Hydro
Panel
Improper installation and/or operation,
or installation by an unqualified person,
will void the warranty.
WARNING
If the information in this manual is not
followed exactly, a fire or explosion may
result, causing property damage,
personal injury, or death.
Hydro-Smart Inc.
15970 Jarvis St NW,
Elk River, MN 55330
Toll Free: (800) 355-4945
1
only,
"Integrator".

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 170 and is the answer not in the manual?

Questions and answers

Beth Walsh
February 17, 2025

What year was the hydro smart 170 gas bouler system come out

Subscribe to Our Youtube Channel

Summary of Contents for Hydro-Smart 170

  • Page 1 Elk River, MN 55330 Toll Free: (800) 355-4945 Please make sure the proper gas pressure guidelines and recommendation from Hydro-Smart failure to do so can cause a fire or explosion and may result, causing property damage, personal injury, or death.
  • Page 2: Table Of Contents

    *In accordance with ANSI Z21.10.3 and SCAQMD Rule 1146.2, CO emission does not exceed 400 PPM for normal input Hydro-Smart reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
  • Page 3 • If you have any problems or questions regarding this equipment, consult with Hydro- Smart. • Hydro-Smart 170 is a micro boiler designed to be used with radiant heating in a combination Hydro Panel. • • This product is only to be used with Hydro-Smart Heating Panels, “Integrator”.
  • Page 4: Safety Guidelines

    National Electrical Codes: ANSI/NFPA 70 in the USA or CSA standard C22.1 Canada Electrical Code Part 1 in Canada. Carefully plan where you intend to install your Hydro-Smart 170. Please ensure: • Your Hydro-Smart 170 will have enough combustible air and proper ventilation.
  • Page 5: Installation

    INSTALLATION All gas Hydro-Smart 170 require careful and correct installation to ensure safe and efficient operation. This manual must be followed exactly. Read the “Safety Guidelines” section at the beginning of this manual. • The warranty will not cover damage caused by water quality. Water hardness that leads to scale formation and/or corrosion may affect/damage the Hydro-Smart 170.
  • Page 6: General

    Hydro-Smart 170 to a sealed combustion unit. Direct venting allows the Hydro-Smart 170 to draw fresh intake air from the outside. The warranty will not cover damage caused to the unit due to installation in a contaminated environment that has not been converted using the TK-TV10.
  • Page 7: Warning For Installation Locations

    Do not locate into the flue terminal. This may cause your Hydro-Smart 170 in a pit or location damage to the Hydro-Smart 170 and void the where gas and water can accumulate.
  • Page 8: Natural Gas Pressure

    • If a mechanical fan or make up air device is used to supply air to the Hydro-Smart 170 or utility room, the installer should make sure it does not create drafts which could cause nuisance shutdowns.
  • Page 9: Inlet

    The Hydro-Smart 170 must be installed in a location where the proper amount of combustible air will be available to it at all times without obstructions. • If used as a direct vent appliance, the Hydro-Smart 170 requires a 3” combustible air supply pipe. The intake pipe must be sealed airtight. •...
  • Page 10: Venting Instructions

    This Hydro-Smart 170 must be vented in accordance with the section “Venting of Equipment" of the latest edition of the Natural Fuel Gas Code: The ANSI Z223.1, All applicable local building codes, Section 7 of the CAN/CSA B149.1 Natural Gas in Canada, Propane Installation Code in...
  • Page 11: Vent Termination

    Do not cut the vent collar of the unit. The weight of the vent stack must not rest on the Hydro-Smart 170. The vent must be easily removable from the top of the Hydro-Smart 170 for normal service and inspection of the unit.
  • Page 12 • Install a condensation drain in the venting. • Follow the vent system to vent manufacturer’s instruction and local code. • Do not common vent or connect any vent from other appliances to the Hydro-Smart 170 vent. • Use 4” category III approved or Special BH, single or double wall stainless steel vent pipe.
  • Page 13 VENT CLEARANCES Canada U.S.A Direct vent and other than Direct Direct vent Other than Direct Vent Vent Clearance above grade, veranda, porch, 1 foot 1 foot 1 foot deck, or balcony. 4 feet from below or Clearance to window or door that may be 3 feet 1 foot side opening.
  • Page 14 ADDITIONAL CLEARANCES Exhaust and/or direct-vent sidewall terminations should be at least 2 ft. away from an opposite surface/wall. Do not place the termination directly in front of an opening into a building. 2ft. Exhaust termination...
  • Page 15: Gas Supply And Gas Pipe Sizing

    GAS SUPPLY AND GAS PIPE SIZING TO TURN OFF GAS TO APPLIANCE 1. Turn off all electric power to the Hydro-Smart 170 if service is to be performed. 2. Turn the manual gas valve located on the outside of the unit clockwise to the off position.
  • Page 16 Otherwise, flow capabilities and output temperatures will be limited. Install a manual gas shut-off valve between the Hydro-Smart 170 and the gas supply line. When the gas connections are completed, it is necessary to perform a gas leak test either by applying soapy water to all gas fittings and observing for bubbles or by using a gas leak detection device.
  • Page 17: Water Connections

    All pipes, pipe fittings, valves and other components, including soldering materials, must be suitable for potable water systems. A manual shut off valve must be installed on the cold water inlet to the Hydro-Smart 170 between the main water supply line and the Hydro-Smart 170.
  • Page 18: Connection

    Hydro-Smart 170 must be provided for service reasons. (Must comply with local codes). • Connect the power supply to the Hydro-Smart 170 exactly as shown in the wiring diagram; A green screw is provided in the junction box to ground the connection.
  • Page 19: Normal Operation

    • Hydro-Smart also highly recommends the use of a back flow vent damper and/or converting the Hydro-Smart 170 to a direct-vent unit to minimize the amount of cold air entering through the exhaust venting when the Hydro-Smart 170 is off.
  • Page 20: Temperature Settings

    • Only change the switches with the dark squares. The dark squares indicate which direction the dipswitch should be set to. • Do not set to higher than 160°F if you use your Hydro-Smart 170. This will cause damage to the Hydro-smart 170 and void the warranty.
  • Page 21: Maintenance And Service

    • Keep the area around the Hydro-Smart 170 clear. Remove any combustible materials, gasoline or any flammable vapors and liquids. Hydro-Smart recommends having the unit checked once a year or as necessary by a licensed technician. If repairs are needed, any repairs should be done by a licensed technician.
  • Page 22: General Troubleshooting

    GENERAL TROUBLESHOOTING ~ Hydro-Smart 170 ~ PROBLEM POSSIBLE SOLUTIONS • Check for the Hydro-Smart Y Strainer on cold water Unit does not ignite when water goes through the unit. inlet in the system. • Check for reverse connection and cross connection.
  • Page 23 TROUBLESHOOTING – ERROR CODES • The Hydro-Smart 170 is self diagnostic for safety and convenience when trouble shooting. • If there is a problem with the installation or the unit, it will display a numerical error code on the TM-RE30 (if installed) or on the 7-Seg LED at the bottom left corner of the computer board to communicate the source of the problem.
  • Page 24: Wiring Diagram

    WIRING DIAGRAM A wiring diagram is located on the inside front panel of the appliance. Electrical Rating: 120 VAC, 60 Hz Note: If any of the original wiring supplied with this appliance must be replaced, it must be replaced with appliance wiring material (180c) or its equivalent.
  • Page 25: Operating Safety

    A. This Hydro-Smart 170 does not have a pilot. It is equipped with an ignition device that automatically lights the burner. Do not try to light the burner by hand.
  • Page 26 4. Can be carried from other rooms to the main burner by air currents WARNING: Do not install Hydro-Smart 170 where flammable products will be stored. Read and follow Hydro-Smart 170 warnings and instructions. If owner’s manual is missing, contact the retailer or manufacturer.
  • Page 27: Optional Items

    The TM-RE30 Temperature Remote Controller has two functions. It allows the output temperature from the Hydro-Smart 170 to be adjusted within the range of 99 °F to 185 °F, and it also works as a diagnostic tool that will give a concise error code whenever there is a problem with the unit.
  • Page 28: Components Diagram

    COMPONENTS DIAGRAM Case assembly 0 5 2 0 5 1 0 5 1 0 0 4 0 5 2 0 5 0 0 5 2 0 0 3 0 0 2 0 0 6 0 0 1 0 5 1 7 0 6 7 0 7 0 5 3...
  • Page 29: Burner Assembly

    Burner assembly 4 0 1 1 2 4 1 1 5 1 1 4 1 5 1 1 1 7 1 0 1 1 1 2 1 0 7 1 0 6 7 1 6 1 1 8 1 5 1 1 5 6 1 1 6 1 1 9...
  • Page 30 Water way assembly 4 1 0 4 1 5 4 1 1 4 5 9 4 5 2 4 0 3 4 5 1 4 0 9 4 1 2 4 1 3 4 0 1 4 1 4 4 5 6 4 6 0 4 5 4 4 0 7...
  • Page 31: Parts List

    PARTS LIST Item# Part# Description Item# Part# Description EKK1D Case assembly EM167 Wire clamp 60 EKK1J Front cover EKK2X Burner gasket EKJ62 Air blockage plate EKK2K Manifold gasket B EKJ09 Bracket EW003 Screw M4×10 EKJ64 Junction box EW002 Screw M4×10 (Coated) EKK5H Back guard panel EKK37...
  • Page 32 Item# Part# Description Item# Part# Description EW009 Screw M4×6 EKN37 Fuse assembly EW00A Screw M4×3 EKJ66 Junction box inner plate EZF16 O-ring P16 FKM EKK1M Computer board cover EZF15 O-ring P15 FKM EKK0D AC100V wire EZF14 O-ring P14 FKM EKK0Z EH-IG Wire EZF06 O-ring P6 FKM...