Broan VX3000C Installation Tips & User Manual

Broan VX3000C Installation Tips & User Manual

Central vacuum power unit

Advertisement

INSTALLATION TIPS & USER GUIDE
CENTRAL VACUUM POWER UNIT
FOR RESIDENTIAL USE ONLY
!
!
AB0001
M
VX3000C, VX6000C
VX12000C
ODELS
AND
V
.
.
C
V
S
I
I
ISIT WWW
BROAN
CA FOR THE
ENTRAL
ACUUM
YSTEM
NSTALLATION
NSTRUCTIONS
B
-N
T
C
I
.; M
, O
.
.
1-888-882-7626
ROAN
U
ONE
ANADA
NC
ISSISSAUGA
NTARIO
WWW
BROAN
CA
R
:
.
.
EGISTER YOUR PRODUCT ONLINE AT
WWW
BROAN
CA
30042323 rev. 15

Advertisement

Table of Contents
loading

Summary of Contents for Broan VX3000C

  • Page 1 INSTALLATION TIPS & USER GUIDE CENTRAL VACUUM POWER UNIT FOR RESIDENTIAL USE ONLY AB0001 VX3000C, VX6000C VX12000C ODELS ISIT WWW BROAN CA FOR THE ENTRAL ACUUM YSTEM NSTALLATION NSTRUCTIONS .; M 1-888-882-7626 ROAN ANADA ISSISSAUGA NTARIO BROAN EGISTER YOUR PRODUCT ONLINE AT BROAN 30042323 rev.
  • Page 2: Important Safety Instructions

    Under normal working as it should, if it has been dropped, damaged, left operation, the light(s) will be green. (A red light on Broan outdoors, or dropped into water, return it to a Service Center.
  • Page 3: Table Of Contents

    WARRANTY ..................16 CENTRAL VACUUM SYSTEM INSTALLATION INSTRUCTIONS Please visit www.broan.ca for the Central Vacuum System Installation Instructions; including System Planning and Layout, General Installation, Installation in New Construction, Installation in Existing Construction, Tubing System Assembly, Final System Check.
  • Page 4: General Information

    AO0045 electrical tape to secure the wire to the tubing. Tape the wire For more details on inlet installation, visit www.broan.ca approximately every 12" to 18". for the Central Vacuum System Installation Instructions. AO0011...
  • Page 5: Power Unit Installation

    POWER UNIT INSTALLATION 1. Locate power unit within six feet (1.82 m) of a grounded electrical outlet. Broan VX3000C and VX6000C power WARNING units require a 120 V, dedicated 15-amp branch-circuit with a NEMA 5-15R receptacle or a dedicated 20-amp branch Do not install outdoors.
  • Page 6: Fitting Main Line To Power Unit

    The power unit has 4 intake GREEN connections, which 2 of them are factory sealed. GREEN 120 VOLTS CAUTION BLUE Broan VX3000C, VX6000C and VX12000C power BLUE THERMAL CONTROL PROTECTOR units will attach to the lower intake connections. BLACK BOARD See Fig.
  • Page 7: Grounding Instructions

    This appliance is for use on a standard 120 VAC, dedicated 15-amp branch circuit with a NEMA 5-15R receptacle or a dedicated 20-amp branch circuit with a NEMA 5-20R receptacle for Broan models VX3000C and VX6000C. For Broan model VX12000C, a dedicated nominal 240 VAC, individual 20-amp branch circuit with NEMA 6-20R receptacle is required.
  • Page 8: For Models: Vxkit300A, Vxkit600E And Vxkit1200E

    page 8 FOR MODELS: VXKIT300A, VXKIT600E AND VXKIT1200E INSTALLING HOSE HANGER CONNECTING HOSE ’ CONT If not already done, install the hose hanger by following these 3 steps. DUAL VOLTAGE HOSE In addition to connecting into wall inlet (A), dual voltage hose must also be connected to a standard electrical outlet (B).
  • Page 9: For Models: Vxkit600E And Vxkit1200E

    NOTE: If your dual voltage hose is not compatible with your new BN200 power brush, please contact Broan-NuTone Customer service at 1-888-882-7626 to receive a free electrical cord (Part no. CRD400-01) that will enable you to connect your new power brush to your hose.
  • Page 10: How To Use Power Brush/Wand

    page 10 HOW TO USE POWER BRUSH/WAND EDGE CLEANER Brush extends full width for effective edge cleaning along both CAUTION sides of nozzle. To operate, simply run cleaner along edge Always pick up hard or sharp objects by hand board. Rubber bumper protects furniture and baseboards. before using your power brush.
  • Page 11: Maintaining The Power Brush

    page 11 MAINTAINING THE POWER BRUSH HOW TO CHANGE BRUSH ROLL Replace brush roll when brush roll brissles are worn to the WARNING base support bars level. Disconnect electrical supply before servicing or Turn power brush over and using a Phillips no. 2 screwdriver, cleaning the unit.
  • Page 12: For All Models

    (Fig. 11). Holding the pail by the handles, lower it from unit (Fig. 12). Broan model VX3000C has a single indicator light that remains green. The level of pail fill for this model can be 2.
  • Page 13: Emptying The Debris Pail

    Open the door located on the front of the power unit. Reach inside the unit and remove both locking sleeves from the retaining hooks. Carefully pull filter down to remove. NOTE: Broan model VX12000C has two secondary filters. Ensure to remove both filters. B. F ILTER REINSTALLATION To reinstall the secondary filter, reverse the steps described above.
  • Page 14: Troubleshooting Guide

    • Replace hose as required. • 1) Push Reset button while unit is engaged OR • Microprocessor lockup. 2) Unplug unit completely for 60 seconds. NOTE:This applies only to Broan VX6000C and VX12000C. • Low line voltage. • Contact your local Service Center.
  • Page 15: Service Parts

    AL0001 Broan-NuTone also recommends contact Broan-NuTone certified service depot for all replacement parts and repairs. VX3000C VX6000C VX12000C ESCRIPTION 10941189 Pail assembly VS 10941191 Pail assembly TS 10941192 Door assembly 10941199 Latch kit (with screws) 10941232 VS PCB’s assembly (including mother, daughter and screws)*...
  • Page 16: Warranty

    MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. During these time periods, Broan-NuTone Canada will, at its option, repair or replace the power unit or part without charge, which is found to be defective under normal use and service. THIS WARRANTY DOES NOT APPLY TO THE INSTALLATION OR THE PARTS USED IN THE INSTALLED TUBING SYSTEM.

This manual is also suitable for:

Vx6000cVx12000c

Table of Contents