Download Print this page

Honeywell W8600F Installation Instructions page 3

Air cleaner monitor
Hide thumbs Also See for W8600F:

Advertisement

Select Wash Frequency
Use the W8600F DIP switches to program the time
between SERVICE indications. Be sure to select the
setting according to the conditions of the home. Factors
to consider include the duty cycle of the EAC, the
number of people and pets, and activities such as
woodworking and other crafts that are being done in the
home.
Refer to Table 2 to select the wash frequency. Set the
W8600F DIP switches to match the selection. See Fig. 4.
The time listed represents actual run time of the EAC, not
calendar days.
Table 2. Wash Frequency Options.
DIP Switch Settings
1
2
Off
Off
On
Off
Off
On
On
On
Off
Off
On
Off
Off
On
On
On
BACK OF W8600F
UP
1 2 3
1
3
Fig. 4. Back of W8600F.
Wiring
1. Run a 3 -conductor thermostat cable (up to
18 gauge) from the W8600F to the terminal strip on
the air cleaner.
IMPORTANT
Connect cable to W8600F before attaching to
the air cleaner terminals to minimize the risk of
damage due to static electricity.
2. Connect the wires to terminals E1, E3 and E4 on
the W8600F. See Fig. 4.
Wash Frequency
3
Days (Run Time)
Off
10
Off
20
Off
30
Off
40
On
50
On
70
On
100
On
180
BATTERY
IN HOLDER
DIP SWITCHES
WIRING
TERMINALS (3)
RESET BUTTON
4
M11969A
W8600F AIR CLEANER MONITOR
3. Check that the battery is correctly installed in the
W8600F battery holder.
4. Snap the W8600F onto the base.
5. Turn off the power for the EAC.
WARNING
Electric Shock Hazard.
Can cause electrical shock or equipment
damage.
Disconnect EAC power and open the access
door before opening power supply box cover.
6. Open the power supply box cover.
7. Remove the plug from the side of the power supply
box (plug can be a metal knockout or a blank termi-
nal strip).
8. Install the terminal block/cable assembly supplied
with W8600F kit.
9. Plug the connector on the end of the cable assem-
bly into the J2 terminal on the driver board
(included with W8600F kit). See Fig. 5.
POWER SUPPLY
BOX COVER
TERMINAL
STRIP
MOUNTING
SCREW
Fig. 5. Installing the driver board on the EAC.
10. Plug the driver board assembly into the J1 power
supply connector.
NOTE: This W8600F kit is configured to operate with a
power supply that is controlled by an airflow
switch (AFS). If your application does not have
an AFS, place the black shorting bar (found in
the bag assembly) on power supply connector
J3, pins 1 and 2, as shown in Fig. 6.
J3
4
3
Fig. 6. Placing shorting bar on power supply for
applications without AFS.
11. Replace the power supply box cover.
3
DRIVER
BOARD
J2
J1
POWER
SUPPLY
POWER SUPPLY BOX
SHORTING BAR
2
1
M20890
M11970
69-1200—2

Advertisement

loading