W8600F AIR CLEANER MONITOR
EAC
F52-ATTIC
Mounting
The following mounting instructions assume that the
W8600F is mounted next to a T8600 Thermostat. If
installing the monitor at another location, modify the
procedure to fit the installation.
1. Hold the mounting template (included in the
W8600F kit) next to the T8600 as shown in Fig. 3.
2. Mark the holes for the screw anchors and the
3-conductor thermostat cable.
3. Remove the template and drill the holes.
4. Remove the W8600F from the base.
5. Position the W8600F base over the holes and
install the anchors and screws (included in the bag
assembly). Tighten the screws until the base is
mounted firmly on the wall.
69-1200—2
RETURN AIR DUCT
W8600F
W8600F
Fig. 2. W8600F mounting locations.
W8600F
W8600F
EAC
EAC
CLOSET
THERMOSTAT
WALLPLATE
MOUNTING HOLES (2)
Fig. 3. Positioning mounting template.
2
EAC
CEMENT BLOCK WALL
W8600F
EAC
GARAGE/DRYWALL
M11966
MOUNTING
TEMPLATE
WIRING HOLE
M11971