Download Print this page

Care Instructions - American Standard Williamsburg 2904 Installation Instructions Manual

Centerset lavatory faucet with speed connect drain

Advertisement

9
TEST INSTALLED FITTING
With HANDLES (1) in OFF position, turn on WATER
SUPPLIES (2) and check all connections for leaks.
Remove AERATOR (3).
Operate both HANDLES (1) to flush water lines thoroughly.
Replace AERATOR (3).
CHECK DRAIN CONNECTIONS
Operate POP-UP KNOB (4) and fill lavatory with water.
Check that DRAIN STOPPER (5) makes a good seal
and retains water in SINK. If DRAIN STOPPER (5)
does not seal properly, please refer to Troubleshooting
section in these instructions.
Release POP-UP KNOB (4) down and check all drain
connections and "P" trap for leaks. Tighten
if necessary.
10
INSTALLATION OF OPTIONAL METAL LEVER HANDLES
(Supplied with Faucet)
Thread PORCELIAN LEVER HANDLE (2) counter-clockwise
and remove INDEX BUTTON with MOUNTING ROD ASSEMBLY (1),
HANDLE COLLAR (4) and O-RING (5).
Insert MOUNTING ROD ASSEMBLY (1) into METAL HANDLE (3),
HANDLE COLLAR (4) and O-RING (5).
Thread HANDLE ASSEMBLY (6) into ball of HANDLE BASE (7).
Apply pressure to the MOUNTING ROD ASSEMBLY (1)
while turning the HANDLE COLLAR (4), in order to tighten
firmly.
11
SERVICE
To change direction of handle rotation,
proceed as follows:
Turn valve to OFF position.
Pull out INDEX CAP and remove
HANDLE SCREW.
Remove SPRING CLIP .
Lift STOP WASHER, turn 90˚ and replace.
Replace SPRING CLIP .
Replace ADAPTER, HANDLE, SCREW, and INDEX CAP .
AERATOR may accumulate dirt causing distorted and
reduced water flow. Remove AERATOR and rinse clean.
If spout drips, operate handles several times from OFF
to ON position. Do not force - handles turn only 90
12

CARE INSTRUCTIONS:

DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
90
STOP
WASHER
SPRING
CLIP
.
˚
1
WASTE
OUTLET
2
2
3
1
6
ALIGN HANDLES
Pull out INDEX CAP (1) and remove
HANDLE SCREW (2), HANDLE (3)
and ADAPTER (4).
Push ADAPTER (4) on VALVE STEM (5).
Find correct position of HANDLE (3) by
adjusting male teeth on ADAPTER (4) to
female teeth on HANDLE (3).
Replace HANDLE SCREW (2) and push
in INDEX CAP (1).
4
4
1
5
"P" TRAP
7
5
4
M 9 6 8 4 2 3 R e v . 1 . 2
3
2
1
2
3
4
5

Advertisement