Savio Savio PLUS PLUS WALL HUNG GAS BOILER FOR CENTRAL HEATING SUPPLY Please Read Instructions Carefully Save for Future Reference WARNING: If the information in this manual is not followed exactly, a fi re or explosion may result causing property dam- age, personal injury or loss of life.
Page 2
All SAVIO wall hung boilers are built in accordance with the ASME boiler and pressure vessel code, and bear the “H” stamp. The Entire range of applications for the SAVIO Plus has been tested to standard CSA 4.9 and is CSA compliant.
Caution: Do not use this boiler if any part has been under water. Immediately call a qualifi ed service technician to inspect the boiler and to replace any part of the control system and any gas control which has been under water. SAVIO PLUS USER MANUAL...
Page 5
If any of the symptoms of CO occur, or if any of the signs of carbon monoxide are present, VACATE THE PREMISES IMMEDIATELY AND CONTACT A QUALIFIED HEATING SER- VICE COMPANY OR THE GAS COMPANY OR THE FIRE DEPARTMENT. ONLY QUALIFIED, LICENSED SERVICE CONTRACTORS SHOULD PERFORM WORK ON YOUR SAVIO PLUS BOILER. SAVIO PLUS USER MANUAL...
- B149 Installation Codes E. ANSI/ASME - CSD-1 The above codes are available from: National Fire Protection Association (NFPA) CSA International Battery March Park 8501 E. Pleasant Valley Road Quincy, Massachusetts, 02269 Cleveland, OH 44134-5575 http://www.nfpa.org http://www.csa-international.org SAVIO PLUS USER MANUAL...
General Information The SAVIO Plus is a high ef ciency condensing, wall mounted gas boiler which provides cen- tral heat. The boiler features a gas valve which modulates the energy input from 49,476 BTU/h to 116,008 BTU/h. The boiler is shipped fully assembled. All units are pressure and combustion tested at the factory prior to shipping.
Flue pipe free air Flue pipe diameter Hot water pipes 1” 2.25/4 Coaxial 3.25/5 Twin split pipes 3.25/3.25 Nominal heat ow rate 116.0 Nominal heat ow rate 110.2 (2000/4500ft) Min Exhaust temperature °F Max Exhaust temperature °F SAVIO PLUS USER MANUAL...
Lack of burner ignition (no ignition signal from the full se- quence ignition device) Ignition gas pressure adjustment Minimum gas pressure adjustment Flashing lamp, alone Flashing lamp, al- Lamp OFF Lamp ON or simultaneously ternate with another with another lamp. lamp 10 SAVIO PLUS USER MANUAL...
You may also nd it necessary to vent air from your heating circuit using the installed vents, however be aware that excessive venting will cause the pressure in the system to drop. Always ensure that the pressure gauge is set at the required pressure. SAVIO PLUS USER MANUAL...
Page 12
These adjustments must be carried out by a quali ed person; there- fore we advise you to contact your install- er or Service Agent. Figure 5.3 12 SAVIO PLUS USER MANUAL...
Shut off the gas supply cock connected to the gas inlet pipe and the cock connected to the supply cold water inlet pipe (see section 3.3 for pipes) • Empty the water circuit, if necessary, as shown in the installation, operation and service instructions manual in the maintenance section. SAVIO PLUS USER MANUAL...
• pressurization of the expansion vessel; • lling up of the central heating circuit; • bleeding of air from the central heating system; • general check of the appliance’s operation. 14 SAVIO PLUS USER MANUAL...
It is necessary to ll up the appliance with water again, so as to raise the pressure to an adequate level as described in the section 5.2 of this manual. • If lling up with water has to be done very frequent, have the system checked for leaks. SAVIO PLUS USER MANUAL...
Authorised Service Person. In case of problems other than those mentioned here, switch off the boiler, as described in Section 5.5 on page 13 and call a competent and responsible service person. 16 SAVIO PLUS USER MANUAL...
Protection, fi ll in and mail this card, within 1 year of installation to the address listed below NAME:____________________________________ ADDRESS:____________________________ CITY:______________________ STATE:________ ZIP:______________ BOILER SERIAL NO.: _______________________ DATE OF INSTALL:_____________________ NAME OF INSTALL CO.:_____________________ ADDRESS:____________________________ CITY:______________________ STATE:________ ZIP:____________ RETURN TO: BOYERTOWN FURNACE Co. PO Box 100 BOYERTOWN, PA 19512 1-610-369- 1450 SAVIO PLUS USER MANUAL...